York TM9Y Technical Guide
TECHNICAL GUIDE
96% AFUE TWO STAGE STANDARD ECM
RESIDENTIAL GAS FURNACES
MULTI-POSITION
MODELS: TM9Y
NATURAL GAS
40 - 120 MBH INPUT
Due to continuous product improvement, specifications are
subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY SUMMARY
A 20-year limited warranty on heat exchangers in residen-
tial applications.
A 10-year warranty on the heat exchanger in commercial
applications.
Standard 5-year limited Parts warranty.
Extended lifetime heat exchanger and 10-year limited
parts warranty when product is registered online within
90 days of purchase for replacement or closing for new
home construction.
See Limited Warranty certificate in Users Information Manual for details.
5129599-YTG-A-0815
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized steel tubular
primary heat exchangers. The units are factory shipped for
installation in upflow or horizontal applications and may be con-
verted for downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV listed and may be vented either
through side wall or roof applications using approved plastic
combustion air and vent piping.
FEATURES
•
Two stage heating operation includes two stage gas valve,
two stage inducer operation and constant torque standard
ECM blower operation. Adjustable delay timer allows two
stage operation with a single stage thermostat.
•
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
•
Compact, easy to install, ideal height 33" tall cabinet.
•
Standard ECM constant torque drive for cooling SEER
enhancement, improved comfort with optional airflow delay
profiles, and continuous fan options for IAQ performance.
•
Easy access to controls to connect power/control wiring.
•
Built-in, high level self diagnostics with fault code display.
•
Low unit current draw requirement for easy replacement
application.
•
All models are convertible to use propane (LP) gas.
•
Electronic Hot Surface Ignition saves fuel use with
increased dependability and reliability.
•
100% shut off main gas valve for extra safety.
•
24V, 40 VA control transformer and integrated furnace con-
trol supplied for add-on cooling.
•
Hi-tech tubular aluminized steel primary heat exchanger
with stainless steel tube/aluminum fin secondary heat
exchanger for outstanding efficiency.
•
Solid removable bottom panel allows easy conversion.
•
Airflow leakage less than 1% of nominal airflow for duct
blaster conditions.
•
No knockouts to deal with, making installation easier.
•
Movable duct connector flanges for application flexibility.
•
Quiet inducer operation, burner, and blower operation.
•
Inducer rotates for easy conversion of venting options.
•
Fully supported blower assembly for easy access and
removal of blower.
•
External air filters used for maximum flexibility in meeting
customers IAQ needs.
•
Insulated blower compartment for thermal and acoustic per-
formance.
•
1/4 turn knobs provided for easy independent door removal.
•
Internal condensate trap design (patent pending) provides
condensate management options and is self priming to pre-
vent nuisance problems.
•
Protection included from air intake, exhaust vent or conden-
sate blockage.
•
Venting applications maybe installed as either 2 pipe sealed
combustion or single pipe vent using indoor combustion air.
Also See for York TM9Y
Related Manuals for York TM9Y
-
Bryant Furnace PLUS 90X 353AAV User's Manual
22 pages
-
Bryant Furnace 310AAV Service Manual
45 pages
-
Bryant Furnace 915SA Product data
16 pages
-
Bryant Furnace 350MAV User's Manual
12 pages
-
Bryant Furnace PLUS 95S 355CAV Owner's Manual
14 pages
-
Carrier Furnace WEATHERMAKER 8000 58ZAV Instruction Manual
24 pages
-
Coleman Furnace DGAA User's Manual
14 pages
-
Goodman Mfg Furnace GMS90453BXA Parts list
11 pages
-
Rheem Furnace CRITERION II Installation Manual
8 pages
-
Trane Furnace XR 90 SERIES Owner's Manual
16 pages
-
Carrier Furnace 58GS User's Manual
12 pages
-
Carrier Furnace 58MCB User's Manual
12 pages
-
Rinnai Furnace ENERGYSAVER ES38 User's Manual
44 pages
-
Bryant Furnace Condensing s 398AAV User's Manual
12 pages
-
Thermo Products Furnace Thermo Pride Furnace OL6RA072D48(B/R) User's Manual
75 pages
-
Thermo Products Furnace OL5-85 User's Manual
32 pages
-
Thermo Products Furnace Thermo Pride Furnace MHA1-75N User's Manual
61 pages
-
Atwood Mobile Products Furnace HYDRO FLAME 8935 User's Manual
7 pages
-
Atwood Mobile Products Furnace HYDRO FLAME 8940 User's Manual
7 pages
-
Westinghouse Furnace FG7TC 95.1% AFUE Two-Stage Technical Literature
8 pages
-
Maytag Furnace PGC2TC PGC2TL | Maytag M1200 95.1% AFUE Two-Stage Fixed-Speed Gas Furnace Technical Literature
8 pages
-
Rinnai Furnace EX22C (RHFE-559FTA) Installation and Operation Manual
84 pages
-
York Furnace TM9E User's Manual
8 pages
-
GAMA Furnace Gas-Fired Furnace User's Information Manual
40 pages