White Rodgers 956 User's Manual
INSTALLATION
To remove the old cell from the bracket:
Disconnect wires from terminals on primary control.
Rotate cell counterclockwise in bracket.
Slide the cell out of the bracket through the notched
opening in the bracket.
To install new cell:
Insert new cell through notched opening in bracket.
Rotate cell clockwise to lock into position.
Connect wires to terminals on primary control.
All wiring must conform to local and national electrical codes and ordinances.
Make electrical connections to F-F terminals on primary control.
Wiring
Do not disturb the bracket position during re-
placement of cell assembly.
If bracket is moved or new bracket is installed, follow the
equipment manufacturers' recommendations for proper
positioning.
Cell assembly cannot be installed properly if bracket is
installed backwards.
CAUTION
!
NOTE
To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.
Label all wires prior to disconnection when ser-
vicing controls. Wiring errors can cause improper
and dangerous operation
Following installation or replacement, follow
appliance manufacturers’ recommended instal-
lation/service instructions to insure proper
operation.
Printed in U.S.A.
PART NO. 37-5766A
9712
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD ST. LOUIS, MO 63123-5398
(314) 577-1300 FAX (314) 577-1517
WHITE-RODGERS
956 SERIES
Flame Detector
INSTALLATION INSTRUCTIONS
This solid-state electronic flame detector utilizes light
intensity to sense the presence of the flame in oil burning
systems.
Operator: Save these instructions for future use!
PRECAUTIONS
THIS DETECTOR MUST BE INSTALLED BY A QUALI-
FIED INSTALLER.
All wiring must conform to local and national electrical
codes and ordinances.
This detector is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the detector to malfunction.
Do not use on circuits exceeding specified volt-
ages. Higher voltages will damage unit and could
cause shock or fire hazard.
If in doubt about whether your wiring is millivolt,
low or line voltage, have it inspected by a quali-
fied heating and air conditioning contractor or a
licensed electrician.
CAUTION
!
WARNING
!
On flame failure, the detector will cause the primary
control to shut down the main burner. This flame detector
can be interchanged with similar type flame detectors.
Related Manuals for White Rodgers 956
-
Firex Smoke Alarm i4618 Series User's Manual
18 pages
-
Firex Smoke Alarm i4618A Series User's Manual
19 pages
-
First Alert Smoke Alarm SC9120B User's Manual
11 pages
-
First Alert Smoke Alarm SA710 User's Manual
6 pages
-
Honeywell Smoke Alarm FIRE-LITE 411UDAC Installation Manual
88 pages
-
Kidde Smoke Alarm i12060A User's Manual
18 pages
-
Kidde Smoke Alarm 1276 User's Manual
7 pages
-
Universal Security Instruments Smoke Alarm USI-5204 User's Manual
8 pages
-
Kidde Smoke Alarm i12060 User's Manual
17 pages
-
Kidde Smoke Alarm i9080 User's Manual
18 pages
-
Kidde Smoke Alarm 1235 User's Manual
6 pages
-
Firex Smoke Alarm I240C User's Manual
8 pages
-
Bosch Smoke Alarm FPD-7024 User's Manual
122 pages
-
Honeywell Smoke Alarm Photoelectronic Smoke/Temperature Detector 5808W3 User's Manual
4 pages
-
Siemens Smoke Alarm Synova FC330A User's Manual
58 pages
-
Siemens Smoke Alarm FP-11 User's Manual
4 pages
-
BRK electronic Smoke Alarm 4919 User's Manual
2 pages
-
System Sensor Smoke Alarm 2W-B User's Manual
4 pages
-
Orbit Manufacturing Smoke Alarm Rokonet ORBIT-6 RP-206 User's Manual
37 pages
-
Apollo Smoke Alarm XP95 User's Manual
24 pages
-
LST Smoke Alarm Series BC216 User's Manual
73 pages
-
LST Smoke Alarm Vds EN 12094-1 User's Manual
4 pages
-
Kidde Smoke Alarm I12040 User's Manual
17 pages
-
Firex Smoke Alarm i4618A Series User Manual
19 pages