White Rodgers 956 User's Manual

White Rodgers Smoke Alarm User's Manual - 956.
Download
Page  of 3
4.8, 1547 votes
background image

INSTALLATION

To remove the old cell from the bracket:

Disconnect wires from terminals on primary control.

Rotate cell counterclockwise in bracket.

Slide the cell out of the bracket through the notched
opening in the bracket.

To install new cell:

Insert new cell through notched opening in bracket.

Rotate cell clockwise to lock into position.

Connect wires to terminals on primary control.

All wiring must conform to local and national electrical codes and ordinances.

Make electrical connections to F-F terminals on primary control.

Wiring

Do not disturb the bracket position during re-
placement of  cell assembly.

If bracket is moved or new bracket is installed, follow the
equipment manufacturers' recommendations for proper
positioning.

Cell assembly cannot be installed properly if bracket is
installed backwards.

CAUTION

!

NOTE

To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.

Label all wires prior to disconnection when ser-
vicing controls. Wiring errors can cause improper
and dangerous operation

Following installation or replacement, follow
appliance manufacturers’ recommended instal-
lation/service instructions to insure proper
operation.

Printed in U.S.A.

PART NO. 37-5766A

9712

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD ST. LOUIS, MO 63123-5398
(314) 577-1300  FAX (314) 577-1517

WHITE-RODGERS

956 SERIES
Flame Detector

INSTALLATION INSTRUCTIONS

This solid-state electronic flame detector utilizes light
intensity to sense the presence of the flame in oil burning
systems.

Operator: Save these instructions for future use!

PRECAUTIONS

THIS DETECTOR MUST BE INSTALLED BY A QUALI-
FIED INSTALLER.

All wiring must conform to local and national electrical
codes and ordinances.

This detector is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the detector to malfunction.

Do not use on circuits exceeding specified volt-
ages. Higher voltages will damage unit and could
cause shock or fire hazard.

If in doubt about whether your wiring is millivolt,
low or line voltage, have it inspected by a quali-
fied heating and air conditioning contractor or a
licensed electrician.

CAUTION

!

WARNING

!

On flame failure, the detector will cause the primary
control to shut down the main burner. This flame detector
can be interchanged with similar type flame detectors.

0.496542s