White Rodgers 50A55-743 Drop-In Direct Replacement Furnace Control Catalog Page

White Rodgers Heaters Catalog Page - 50A55-743 Drop-In Direct Replacement Furnace Control.
Download
Page  of 1
4.2, 2298 votes
background image

GOODMAN 

INTEGRATED HSI MODULE

DIRECT 

REPLACEMENT

50A55-743

50A55-743 GOODMAN SILICON CARBIDE SINGLE 

STAGE INTEGRATED HSI FURNACE CONTROL

ControlsGasValve,Ignitor,Blower,Inducer,Humidifier

(Both 120V & 24V Input), and Air Cleaner. Replaces OEM   

Goodman and White-Rodgers Models

FEATURES
•Includesflashcodediagnostics.

•Twinningconnection.

•Fusedtoprotectlowvoltagesystemtransformer

SPECIFICATIONS
Operating Temperature. . . . . . . . . . . . . . . . . . .   -40 to 176°F

Humidity Range  . . . . . . . . . . . . . . . . . . . . . . . .   5% to 93% RH (non-condensing)

Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   Snap in standoffs
Electrical Ratings @ 77°F (25°C)

Input Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . .   25 VAC 50 / 60 Hz

Maximum Input Current @ 30 VAC  . . . . . . . . .   0.45 amp
Relay Load Ratings

Valve Relay. . . . . . . . . . . . . . . . . . . . . . . . . . . .   1.5 amp @ 25 VAC 50 / 60 Hz 0.6 pf

Ignitor Relay . . . . . . . . . . . . . . . . . . . . . . . . . . .   6.0 amp @ 120 VAC 50 / 60 Hz

Inducer Relay . . . . . . . . . . . . . . . . . . . . . . . . . .   2.2 FLA-3.5 LRA @ 120 VAC

Circulator Relay  . . . . . . . . . . . . . . . . . . . . . . . .   14.5 FLA-25.0 LRA @ 120 VAC
Flame Current Requirements

Minimumcurrenttoinsureflamedetection. . . .   1 uA DC

Maximum current for non-detection  . . . . . . . . .   0.10 uA DC

Maximumallowableleakageresistance. . . . . .   100 M ohms
Timing Spec (@ 60 Hz)                                       maximum

Flame establishing time  . . . . . . . . . . . . . . . . . .   0.8 sec 

Flame failure response time . . . . . . . . . . . . . . .   2.0 seconds
NOTE:At50Hz,alltimingspecificationsshouldbeincreasedby20%.

Model 

Number

Pre-Purge

Time

Heat

Delay On

Heat Delay

Off Sec.

Cool Delay

On Sec.

Cool Delay

Off Sec.

Post

Purge

50A55-743 15 seconds

30

90 / 120 / 150 /180

5

45

15 sec

50A55-743 Replaces:

0130F00005

PCBBF110

0130F00005S

PCBBF110S

50A55-289

PCBBF112

50T55-289

PCBBF112S

B1809926

PCBBF123

B1809926S

PCBBF123S

CROSS REFERENCE

NOTE: Can also use Universal Kit 50M56U-843

www.white-rodgers.com