White Rodgers 36h User's Manual

White Rodgers Boat User's Manual - 36h.
Download
Page  of 24
4.9, 1710 votes
background image

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY 

BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE 

PERSONAL INJURY AND/OR PROPERTY DAMAGE.

The

 36H series gas valve has redundant and main 

solenoid valves that control gas flow to the main 
burners, a pressure regulator to maintain a constant 
outlet pressure, and a two position on/off switch for 
electrical shutoff. The valves are shipped from the fac-
tory set for natural gas non-piloted applications. 
See instructions in this document for modifications 
required if the valve is to be installed on an LP gas 
and/or piloted gas application.

36H SERIES

Universal Replacement Electronic Ignition Gas Valve

INSTALLATION INSTRUCTIONS

CONTENTS

Description  ..................................................... 

1

Specifications  ................................................. 

1

Precautions  ..................................................... 

3

Installation ...................................................... 

4

 

System Wiring

Adjustment  ..................................................... 

7

 

Pressure Regulator Adjustment

Lighting Instructions ........................................

 8

Contents French  ............................................. 

9

Contents Spanish  .......................................... 

17

T

ype of Gas: ......................   Natural Gas

Ambient Temperature:  ....  

-40° to 175°F

Pressure Rating: ...............  

14” W.C. (1⁄2 PSI) max.

Voltage: ............................  

24 VAC

Frequency: .......................  

50/60 Hz

Current: ............................   Single Stage - 

.410A

                                                            Two-Stage - 

.540A

Model 

No.

No. of 

Stages

Open

Characteristics

Proven/ 

Intermittent 

Pilot

HSI DSI

36H32

1

Fast

Yes

Yes Yes

36H33

1

Slow

Yes

Yes Yes

36H64

2

Fast

Yes

Yes Yes

36H65

2

Slow

Yes

Yes Yes

Pressure Regulator Adjustment Range ( in W.C.)

Single 

Stage

Two Stage

Low

High

Min Diff.

Low to High

Natural Gas

2.5 - 5.0

1.0 - 3.5

2.5 - 5.0

1.5

LP Gas

5.0 - 12.0

4.0 - 9.5

8.0 - 12.0

2.5

PIPE SIZES/CAPACITIES

Pipe Sizes 

Available (inches)

Capacity (BTU/hr) at 

1” W.C.

pressure drop across valve

AGA Std. Nat. Gas

(

1,000 btu/ cu. ft.)

LP. Gas 

(

2,500 btu/cu. ft.)

3/4” x 3/4” NPT 

300,000

486,000

1/2” x 3/4” NPT 

260,000

421,000

 

 

SPECIFICATIONS

 

 

DESCRIPTION

www.white-rodgers.com

www.emersonclimate.com

PART NO. 

37-7336A

1219