Pilot Gas Outlet:

Located at outlet end of the valve

Type of Gas

Suitable for all domestic heating gases

Pressure Rating: 1/2 lb. per sq. in.

Pressure Regulator Adjust Range (Typical, See

Control Label):
Natural Gas: 2.5 to 5.0" W.C.
LP Gas:

7.5 to 12" W.C.

Ambient Temperature: -40° to 175°F

Thermocouple:

 (24V & 120V types): Use W-R Type HO6

(.750V Quick Drop Out Power Unit for
36D34 models only): 
Use W-R Type H19E

Pilot Generator (.750 volt types):

Use W-R Type G01A-32

Mounting:  Any position except upside-down

PIPE SIZES/CAPACITIES

Pipe Size

(inches)

Capacity (BTU/hr) at

1” pressure drop across valve

1⁄2” x 3⁄8”
1⁄2” x 1⁄2”
1⁄2” x 3⁄4”
3⁄4” x 3⁄4”

100,000
230,000
230,000
280,000

162,000
372,600
372,600
453,600

Nat. Gas

(1000 BTU/cu. ft.,

64 Sp. Gr.)

LP Gas

(2500 BTU/cu. ft.,

1.53 Sp. Gr.)

 INLET BOSS
UP OR DOWN

   UPRIGHT

 LEFT OR RIGHT

Upright, 90

° from upright or vertical

NOTE: Control shown may not be identical

to replacement control.

ON

OFF

www.white-rodgers.com

PART NO. 37-5781D

Replaces 37-5781C

0909

INSTALLATION INSTRUCTIONS

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY
AND/OR PROPERTY DAMAGE.

The 36C03, 36C13 and 36D34 complete gas controls
combine into a single compact package the functions of 3-
position gas cock, pressure regulator, 100% shut-off
automatic pilot, and main operator. Separate models are
available for use on 24 VAC, 120 VAC and .750 VDC
systems. These controls can be mounted in any orienta-
tion except upside down.

MODELS AVAILABLE

Model No.

Voltage

36C03

36C03A
36C03U

36C13

36C13A
36C13U
36D34U

Current

.23 Amp

.035 Amp

DC

.23 Amp

.035 Amp

DC
DC

24 volts

120 volts

.750 volts

24 volts

120 volts

.750 volts
.750 volts

Gas
Nat.
Nat.
Nat.

LP
LP
LP

Nat./LP

OFF

PILOT

ON

ECO

Terminals

OFF

P

IL

OT

ON

The 36C03 and 36C13 models are also available without
pressure regulator as a Model 36C10.

The 36D34 model is limited to .750 VDC applications and
is equipped with a "quick drop out" power unit for vented
gas hearth products.

Operator: Save these instructions for future use!

DESCRIPTION

SPECIFICATIONS

36C03, 36C10, 36C13 and 36D34

Combination Gas Valves

(24 Volt, 120 Volt and .750 Volt Models)