White Rodgers 36C03U-433 Gas Valve Catalog Page

White Rodgers Heaters Catalog Page - 36C03U-433 Gas Valve.
Download
Page  of 1
4.7, 2390 votes
background image

36C Series

PARTS AND ACCESSORIES See end of this section for parts and accessories

36C SERIES

GAS VALVES

GAS BURNER

CONTROLS

?

WIRING 

172–175

HSI/DSI VALVES, INTERMITTANT IGNITION

36C74-913

Step

Open

24VAC Natural 3/4 x 3/4

Step

0.9”/3.5” 2.5”-5.0”

No

No

No

Str. Thru

Yes

Yes

No

5

36C94-303 Intermit-

tent

Ignition

Systems

24VAC Natural

or

LP

1

/2 x 3/4

Delay

Slow

3.5”

2.5”-5.0”

7.0”-12.0”

Yes

Yes

No

Str. Thru

No

Yes

No

15

 Wiring diagrams – see pages 172–175 

 

 Indicates Canadian Model Number 

 

U =  Universal

 

36C SERIES STANDING PILOT SNAP OPEN, STEP 

OPEN, HSI, DSI, AND INTERMITTENT IGNITION  

GAS VALVES

A Wide Range of Replacement Valves for the Professional Installer

SPECIFICATIONS
Electrical Rating . . . . . . . . . . . . . . . . . . . . . . . .   0.23 amps

Ambient Operating Range  . . . . . . . . . . . . . . . .  -40to+175°F(-40to79°C)

Maximum Pressure Rating . . . . . . . . . . . . . . . .   1/2 PSI (14.0” W.C.)

Pilot Gas Connection  . . . . . . . . . . . . . . . . . . . .   1/4”compressionfitting

Pressure Tap  . . . . . . . . . . . . . . . . . . . . . . . . . .   1/8” N.P.T.

Pipe Size

1” Pressure Drop Capacity

Rated Range of Regulation

BTU/HR

BTU/HR

STD. NAT GAS

1000 BTU/CU. FT.

LP GAS

2500 BTU/CU. FT.

STD. NAT GAS

1000 BTU/CU. FT.

LP GAS

2500 BTU/CU. FT.

1/2 X 3/8

100,000

162,000

15,000-100,000

15,000-162,000

1/2 X 1/2

230,000

372,600

30,000-290,000

30,000-469,000

1/2 X 3/4

230,000

372,600

30,000-290,000

30,000-469,000

3/4 X 3/4

280,000

453,600

50,000-400,000

50,000-648,000

SNAP OPEN, SINGLE FUNCTION, STANDING PILOT GAS VALVES

Model

Number

Typical

App.

Coil

Voltage

Gas

Type

Pipe

Size

Opening

Character-

istic

Regulator 

Setting

Regulator 

Adjustment 

Range

Convertible

Nat. / LP

LP 

Conversion 

Kit Included

Line 

Interrupter

Flow

Direction

Reducer

Bushing

Kit

Inlet 

Pressure 

Tap

Side

Taps

Internal 

Wiring See 

Figure 

36C01-405 Snap

Open

24VAC Natural

or

LP

3

/4 x 3/4 Fast Open

3.5”

2.5”-5.0”

Yes

Yes

No

Str. Thru

Yes

No

No

1

36C01A-405 Snap

Open

120VAC Natural

or

LP

3

/4 x 3/4 Fast Open

3.5”

2.5”-5.0”

Yes

Yes

No

Str. Thru

Yes

No

No

3

36C03-300 Standing

Pilot

24VAC Natural

or

LP

1

/2 x 3/4 Fast Open

3.5”

2.5”-5.0”

Yes

Yes

Yes

Str. Thru

Yes

No

No

1

36C03-333 Standing

Pilot

24VAC Natural

or

LP

1

/2 x 3/4 Fast Open

3.5”

2.5”-5.0”

Yes

Yes

Yes

Str. Thru

Yes

No

Yes

1

36C03-400 Standing

Pilot

24VAC Natural

or

LP

3

/4 x 3/4 Fast Open

3.5”

2.5”-5.0”

Yes

Yes

Yes

Str. Thru

Yes

No

No

1

36C03-433 Standing

Pilot

24VAC Natural

or

LP

3

/4 x 3/4 Fast Open

3.5”

2.5”-5.0”

Yes

Yes

Yes

Str. Thru

Yes

Yes

Yes

1

36C03A-410 Standing

Pilot

120VAC Natural

or

LP

3

/4 x 3/4 Fast Open

3.5”

2.5”-5.0”

Yes

Yes

Yes

Str. Thru

Yes

No

No

3

36C03U-333 Standing

Pilot

750mV Natural

or

LP

1

/2 x 3/4 Fast Open

3.5”

2.5”-5.0”

Yes

Yes

Yes

Str. Thru

Yes

Yes

Yes

2

36C03U-433 Standing

Pilot

750mV Natural

or

LP

3

/4 x 3/4 Fast Open

3.5”

2.5”-5.0”

Yes

Yes

Yes

Str. Thru

Yes

Yes

Yes

2

36C04U-438 Standing

Pilot

750mV Natural

or

LP

3

/4 x 3/4 Step Open

0.7"

0.7 / 3.5” 2.5”-5.0”

No

No

Yes

Str. Thru

Yes

No

No

2

36C53-418 Standing

Pilot

24VAC Natural

or

LP

3

/4 x 3/4 Slow Open

3.5”

2.5”-5.0”

Yes

No

Yes

Str. Thru

Yes

No

No

1

36C03-258 Standing

Pilot

24VAC Natural

or

LP

1

/2 x 1/2 Fast Open

3.5”

2.5”-5.0”

No

No

Yes

Str. Thru

No

Yes

No

1

U

U

www.white-rodgers.com

38

HEA

TING

Related Manuals for White Rodgers 36C03U-433 Gas Valve

0.637778s