36C03 (U) -333 and -433 Universal Combination Controls Cross Reference Chart

Manufacturer

Competitor

Part Number

Comments

36C03-333

Robertshaw

700-101

Regulator of replacement is set at 3.5 W.C.; requires use of reducer bushings 
(included)

Robertshaw

700-102

Replacement requires use of reducer bushings (included)

Robertshaw

700-402

Robertshaw

700-419

May require use of reducer bushings (included) and LP conversion kit (F92-0737)

Robertshaw

720-402

Replacement has no side outlet and has 1/2" inlet and 3/4" outlet

Honeywell

V800A 1070

Honeywell

V800A 1484

Order F92-0737 regulated LP kit to achieve 11.0 regulation of replacement

Honeywell

VR8300A 3500

36C03-433

Robertshaw

700-105

Regulator of replacement is set at 3.5 W.C.; may require use of reducer bushings 
(included)

Robertshaw

700-106

Replacement may require use of reducer bushings (included)

Robertshaw

700-185

Regulator of replacement is set at 3.5 W.C.; may require use of reducer bushings 
(included)

Robertshaw

700-401

Regulator of replacement is set at 3.5 W.C.; may require use of reducer bushings 
(included); no side taps

Robertshaw

700-404

Replacement may require use of reducer bushings (included); no side taps

Robertshaw

700-405

Regulator of replacement is set at 3.5 W.C.

Robertshaw

700-407

Regulator of replacement is set at 3.5 W.C.; may require use of reducer bushings 
(included); no side taps

Robertshaw

700-411

Replacement requires use of LP conversion kit (F92-0737); may require use of reducer 
bushings (included); no side taps

Robertshaw

700-412

Replacement may require use of reducer bushings (included) and LP conversion kit 
(F92-0737); no side taps

Robertshaw

720-404

36C03-433 uses HO6E-36 thermocouple

Honeywell

V800A 1088

Honeywell

V800A 1492

Order F92-0737 regulated LP kit to achieve 11.0 regulation of replacement

Honeywell

VR8300A 3518 36C03-433 uses HO6E-36 thermocouple

Honeywell

VR8300A 4508

Honeywell

VR8300A 4516 36C03-433 uses HO6E-36 thermocouple

Honeywell

VR8300M 4505

36C03U-333

Honeywell

VS820A 1336

Honeywell

VS820A 1047

Robertshaw

700-502

36C03U-333 has 1/2" inlet and 3/4" outlet

Robertshaw

700-504

Robertshaw

700-503

Install F92-0737 kit to achieve non-regulated setting

36C03U-433

Robertshaw

700-506

36C03U-400 is also available, 36C03U-400 has no LP kit or bushings

Robertshaw

700-511

Replacement valid for vented applications only

Robertshaw

700-512

Replacement valid for vented applications only

Robertshaw

700-515

Requires use of LP kit (included), replacement valid for vented applications only

Honeywell

VS800A-1054

Honeywell

VS800A-1336

Honeywell

VS800A-1054

Honeywell

VS800A-1336

Part No. 37-6271C