White Rodgers 36C03-333 Gas Valve Installation Instructions

White Rodgers Heaters Installation Instructions - 36C03-333 Gas Valve.
Download
Page  of 24
4.3, 2385 votes
background image

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY 

BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE 

PERSONAL INJURY AND/OR PROPERTY DAMAGE.

The 

36C03 and 36C10 series valves are designed 

to meet requirements for use on standing con-
tinuous pilot systems. 

36C03 combination models 

include a pressure regulator, 

100% shut-off auto-

matic pilot, and main operator. 

36C10 models do 

not have a pressure regulator. 

36C Inst

Voltage

# of 

Stages

Open 

Characteristics

Standing

Pilot

Intermittent Pilot 

Proven Pilot

HSI

DSI

36C03/36C10

24V

1

Fast

Yes

No

No

No

36C03U

750mV

1

Fast

Yes

No

No

No

36C03A

120V

1

Fast

Yes

No

No

No

PRESSURE REGULATOR ADJUSTMENT RANGE

EXCLUDING 

36C10 NON-REGULATED

Gas Type

Single Stage

Natural Gas

2.5–5.0

LP Gas

7.5–12.0

 

 

SPECIFICATIONS

 

 

DESCRIPTION

INSTALLATION INSTRUCTIONS

36C03, 36C03A, 36C03U & 36C10

Standing/Continuous Pilot Combination Gas Valve

OFF

PIL

OT

ON

ECO

Terminals

OFF

PIL

OT

ON

Pilot Gas Outlet: 
 

Located at outlet end of the valve

Type of Gas:  Suitable for all domestic heating  
 

      gases

Ambient Temperature: -

40º to 175ºF

Pressure Rating: 

14" W.C. (1/2 PSI) Max

Voltage/Current: 36C03U – 750mV

                                36C03/36C10 – 24V/0.23A

                                36C03A – 120V/0.035A 

CONTENTS

Description  ........................................................................... 

1

Specifications  ....................................................................... 

1

Precautions ........................................................................... 

2

Installation ............................................................................ 

3

 

System Wiring

Adjustment  .......................................................................... 

5

 

Pressure Regulator Adjustment

Lighting Instructions ............................................................

 6

Contents French ........................................................................9

Contents Spanish.....................................................................17

PIPE SIZES/CAPACITIES

Pipe Size

(inches)

Capacity (BTU/hr) at

1" pressure drop across valve

Range of Regulation

Excluding 

36C10 Non-Regulated

Nat. Gas

(

1000 BTU/cu. ft., 64 

Sp. Gr.)

LP Gas

(

2500 BTU/cu. ft.,

 

1.53 Sp. Gr.)

AGA Std. Nat. Gas

0.64 Sp. Gr.

(

1,000 BTU/cu. ft.)

LP Gas

1.53 Sp. Gr.

(

2,500 BTU/cu. ft.)

1/2" x 3/8"

100,000

162,000

15,000 - 100,000

15,000 - 162,000

1/2" x 1/2"

230,000

372,600

30,000 - 290,000

30,000 - 469,000

1/2" x 3/4"

230,000

372,600

30,000 - 290,000

30,000 - 469,000

3/4" x 3/4"

280,000

453,600

50,000 - 400,000

50,000 - 648,000

Parts and Accessories:
Conversion Kit
• F

92-0659 Nat. to LP Gas (7.5" to 12.0" W.C.)

• F

92-0737 Nat. to LP Gas (Non-regulated)

• F6

9-0727 1/4" brass compression fitting for pilot 

line connection

Thermocouple (

24V & 120V types): 

  Use W-R Type H

06

Pilot Generator (

.750 volt types):

  Use W-R Type G

01A-32

www.white-rodgers.com

www.emersonclimate.com