FURNACE

MERCURY FLAME SENSORS

Prevent Gas Flow to Main Burner if Pilot Flame is Not Burning or Is

Insufficient to Properly Ignite Main Burner
FEATURES
• These sensors combine a rugged Snap-Action switch and powerful mercury

  actuated thermal element.

• May be used with natural, manufactured or mixed gases and with LP gases where

  means are provided for obtaining automatic pilot gas shut-off.

• Switch may be conveniently mounted in any position.

• Cover is easily removed, making switch terminals readily accessible.

• No button to depress – Sensors are recycling type which require relighting or

  possible restoration of proper gas pressure to return to operation.
SPECIFICATIONS
Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . .   Contacts close approximately 60 seconds

   

  after pilot is ignited; open approximately

   

  40 seconds after flame is extinguished

Agency . . . . . . . . . . . . . . . . . . . . . . . . . . .   U.L. recognized and C.S.A. certified,

   

  A.G.A. design certified & C.G.A. certified

Dimensions. . . . . . . . . . . . . . . . . . . . . . . .   23/4”H x 2/6” W x 7/8”D

 

Model 

Element 

Electrical Rating

 

Number 

Length 

120 VAC 

240 VAC 

30 VAC

 

3046-5

 

48” 

25 VA 

25 VA 

90 VA

PLUG-IN TYPE MERCURY FLAME SENSORS

Designed for use with White-Rodgers Diaphragm, “Cushioned Power” 

or “Silent Knight” Gas Valves having Plug-In Receptacle
FEATURES
• Plug-in feature requires no additional electrical connections or mounting devices.

• Sensor combines a rugged Snap-Action SPDT switch and powerful mercury

  actuated thermal element.

• May be used with natural, manufactured or mixed gases and with LP gases where

  means are provided for obtaining automatic pilot gas shut-off.

• No button to depress – Sensors are recycling type which require relighting or

  possible restoration of proper gas pressure to return to operation.

• The SPDT switch can energize ignitor circuit to relight pilot (as with roof top units).
SPECIFICATIONS
Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . .   Contacts close approximately 60 seconds

   

  after pilot is ignited; open approximately

   

  40 seconds after flame is extinguished

Agency . . . . . . . . . . . . . . . . . . . . . . . . . . .   U.L. recognized, A.G.A. design certified

   

  and C.G.A. certified

 

Model 

Element 

Electrical Rating

 

Number 

Length 

120 VAC 

240 VAC 

30 VAC 

Comments

 

30A46-5

 

48” 

25 VA 

25 VA 

90 VA 

stud mount element

  30A46-105 

2” 

25 VA 

25 VA 

90 VA 

sleeve over element,

 

 

 

 

 

 

no stud mount

30A46-5

3046-5

GAS BURNER