TYPE 24A01 / 24A05

“SLIMLINE” LEVEL-TEMP

SILENT OPERATOR

(Normally Open)

INSTALLATION INSTRUCTIONS

Operator:  Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.

A.C.

A.C. MOTOR INDUCTIVE

TYPE

INPUT

THERMOSTAT

RESISTIVE

NUMBER

VOLTAGE /FREQUENCY

CURRENT

NON-INDUCTIVE

24A01G-3

240VAC, 60 Hz

0.2A

25A, 6000W, 240V

12A, 240V

72A, 240V

24A01Z-10

347VAC, 60 Hz

0.2A

17A, 5900W, 347V

24A01Z-11

600VAC, 60 Hz

0.2A

12A, 7200W, 600V

24A05A-1

120VAC, 60 Hz

0.2A

25A, 3000W, 120V

16A, 120V

96A, 120V

24A05E-1

208VAC, 60 Hz

0.2A

25A, 5200W, 208V

12A, 208V

72A, 208V

24A05Z-1

277VAC, 60 Hz

0.2A

22A, 6000W, 277V

FULL LOAD

     LOCKED ROTOR

DESCRIPTION

These “Level-Temp” controls have been designed to
operate with a White-Rodgers low-voltage electric heat
thermostat to provide a system for controlling electric
warm air heaters and electric radiant heating devices
such as duct heaters, wall heaters, baseboards, floor and
ceiling cable heaters.

When required, two or more Level-Temp Silent Opera-
tors can be operated by one two-wire low voltage thermo-
stat.

The operator has been carefully adjusted. No attempt
should be made to adjust it after it leaves the factory.

If in doubt about whether your wiring is millivolt, line, or
low voltage, have it inspected by a qualified heating and
air conditioning contractor, electrician, or someone famil-
iar with basic electricity and wiring.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical
codes and ordinances.

This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.

Do not use on circuits exceeding specified
voltages. Higher voltages will damage control
and could cause shock or fire hazard.

To prevent electrical shock and/or equipment
damage, disconnect electric power to system, at
main fuse or circuit breaker box, until installation
is complete.

CAUTION

WARNING

PRECAUTIONS

SPECIFICATIONS

ELECTRICAL DATA
Switch Action:
 Single-Pole, Single-Throw, normally open
Thermal:  Average time delay – 45 seconds
Ambient Temp.:  -20

° to 140°F (-24° to 60°C)

Room Thermostat:

Set adjustable heat anticipator at 0.2 Amps. For fixed
anticipation thermostats, use 0.15 to 0.25 Amp. heater.

WHITE-RODGERS

Mounting:  1/2" conduit hub or mounting tabs with several break-offs for 2, 3 or 4 hole mounting