DESCRIPTION

1F83-71

Non-Programmable Electronic

Digital Automatic Changeover Multi-stage Thermostat

INSTALLATION AND

OPERATION INSTRUCTIONS

PART NO. 37-6126B

Replaces 37-6126A

0004

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

PRECAUTIONS

SPECIFICATIONS

CAUTION

!

WARNING

!

WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398

WHITE-RODGERS

Your new White-Rodgers Digital Multi-stage Thermostat uses
the technology of a solid-state microcomputer to provide precise
time/temperature control.

Features:

• Simultaneous heat and cool setpoint storage
• Optional C terminal (dual power option)
• Optional B and O terminals
• Preprogrammed temperature control

• LCD continuously displays setpoint and room temperature

°F/°C convertibility

• Temperature range 45

° to 90°F

• Two-stage heat/two-stage cool
• Armchair programming  capability

This thermostat is intended for use with a 24-volt system; do not
use this thermostat with a millivolt or line voltage system.  If in
doubt about whether your wiring is millivolt, line, or low voltage,
have it inspected by a qualified heating and air conditioning
contractor or electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and
ordinances.

This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.

To prevent electrical shock and/or equipment damage
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.

Do not short out terminals on gas valve or primary
control to test.  Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.

ELECTRICAL DATA
Electrical Rating:

20 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.5 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)

THERMAL DATA
Setpoint Temperature Range:

45

°F to 90°F (7°C to 32°C)

Operating Ambient Temperature Range:

32

°F to 105°F

Operating Humidity Range:

0 to 90% RH (non-condensing)

Shipping Temperature Range:

-40

°F to 150°F

APPLICATIONS

For use with:

• Heat/cool systems with up to two stages heat, two

stages cool

DO NOT USE WITH:

• Millivolt systems
• Systems exceeding 30 VAC and 2.5 amps
• 3-wire zoned hydronic heating systems