White Rodgers 1F83-261 Installation and Operation Manual

White Rodgers Thermostats Installation and Operation Manual - 1F83-261.
Download
Page  of 6
4.8, 1471 votes
background image

1F83-261

Non-Programmable Electronic Digital

Multi-Stage Thermostat

INSTALLATION AND OPERATION INSTRUCTIONS

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

• Backlit display when any key is pushed
• °F/°C convertibility
• Temperature range 45° to 90°F
• R, C, W, W2, G , Y and Y2 terminals
• Optional C terminal (Dual Power option)
• Setpoint storage in case of power loss
• 2 “AA” Energizer

® alkaline batteries included

Operator:  Save these instructions for future use!

Your new White-Rodgers Digital Thermostat uses the technol-
ogy of a solid-state microcomputer to provide precise time/
temperature control. This thermostat offers you the flexibility to
design heating and cooling programs that fit your needs.

Features:

• Simultaneous heat and cool setpoint storage
• Pre-set temperature control
• LCD continuously displays setpoint and room temperature

PRECAUTIONS

This thermostat is intended for use with a low voltage system; do
not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contractor
or electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and
ordinances.

This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.

!

CAUTION

To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

!

WARNING

Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.

Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.

Thermostat installation and all components of the
system shall conform to Class II circuits per the NEC
code.

SPECIFICATIONS

ELECTRICAL DATA

Electrical Rating:

20 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.5 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)

THERMAL DATA

Setpoint Temperature Range:

45°F to 90°F (7°C to 32°C)

Operating Ambient Temperature Range:

32°F to 105°F

Operating Humidity Range:

0 to 90% RH (non-condensing)

Shipping Temperature Range:

-4°F to 150°F

APPLICATIONS

For use with:

• Heat/cool systems with up to two stages heat,

two stages cool

DO NOT USE WITH:

• Millivolt systems
• Systems exceeding 30 VAC and 1.5 amps
• 3-wire zoned hydronic heating systems