White Rodgers 150 User's Manual

White Rodgers Thermostats User's Manual - 150.
Download
Page  of 2
4.4, 2059 votes
background image

PART NO. 37-6756A

0610

INSTALLATION INSTRUCTIONS

1G66 and 150

ELECTRIC-HEAT THERMOSTAT

(Double Line Disconnect)

The Type 1G66 Electric Heat Thermostat is designed for use on
all types of electrical heating installations such as cable heat,
baseboards, wall insert heaters, etc.

The Type 1G66 thermostat is intended for use on 240 or 277
VAC where local codes require that a double line disconnect
thermostat be used. This thermostat can also be used on 120
VAC. (See specific wiring information for 120 VAC.)

Dial Setting: This thermostat may be set anywhere between
40° and 80°F by simply turning the knob so the indicator on
knob points to the desired setting.

The knob may be turned past 40° to the “OFF” position to
obtain temporary shutdown of the heating equipment for short
periods of time such as on weekends, vacation, etc. Turning
knob  to “OFF” position will break both sides of line.

NOTE: Only one side of line is broken during normal cycling of
this thermostat.

DESCRIPTION

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY
AND/OR PROPERTY DAMAGE.

SPECIFICATIONS

PRECAUTIONS

80

70

60

50

40

OFF

This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction. Take care not to push or damage
the internal bimetal sensing element during installation.

To prevent electrical shock and/or equipment damage,
disconnect electric power  to system, at main fuse or
circuit breaker box, until installation is complete.

All wiring must conform to local and national electrical codes
and ordinances.

Do not use on circuits exceeding specified voltages.
Higher voltages will damage control and could cause
shock or fire hazard.

Do not use on inductive loads. Inductive (motor) loads
will damage control and could cause shock, fire hazard
or failure of thermostat.

Switch Rating: Non-Inductive

22A (5000W) 240VAC
19A (5000W) 277VAC
22A (2500W) 120VAC

Temperature Range: 40° to 80°F

Differential: 3.0°F

Switch Action: Open on rise

Contact Structure: Double Line Disconnect - DPST

CAUTION

!

WARNING

!

White-Rodgers is a division 

of Emerson Electric Co.

www.white-rodgers.com

This Thermostat includes:

Wall cover plate (required when thermostat will not hide

wall imperfections behind old thermostat)

Two cover mounting screws
Three Temperature Limiting Pins