White Rodgers 1131-102 Well Immersion Single Control Catalog Page

White Rodgers Hydronic & Appliance Catalog Page - 1131-102 Well Immersion Single Control.
Download
Page  of 1
4.5, 1762 votes
background image

HYDRONIC

CONTROLS

WELL IMMERSION SINGLE CONTROL

Types for use as High Limit, Reverse Action or SPDT Switching 

Action: May Be Mounted Either Horizontal or Vertical.

FEATURES
•Extracapillarylengthforextendedshankwells.

•Specialscrewterminalswith“ears”securelyholdsolidandstrandedwires.

•Screwdriver-adjustabledifferentialwithdirect-readindicator.

•Knockoutsontopandbottomandplentyofwiringroom.

•Hydraulicactionelement—fastacting.

SPECIFICATIONS
Dimensions. . . . . . . . . . . . . . . . . . . . . . . .   53/8”H + 25/16” coil x 29/16”D

Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . .   Grey

Agency . . . . . . . . . . . . . . . . . . . . . . . . . . .   U.L. listed and C.S.A. approved

11D18-1

PARTS AND ACCESSORIES See end of this section for additional parts and accessories
•F145-0163—Tubeheatconductivecompound

•Immersionwells—seepage107

 

 

 

 

 

Full 

Motor Rating 

Valves and

 

Model 

 

 

 

Switch 

Electrical 

(Full Load) 

Relays

  Number 

Range 

Differential 

Action 

Rating 

120 VAC 

240 VAC

 

24 VAC 

0.3-12v DC

 

11D18-1  ➀ 

100 to 240°F 

5 to 45°F 

Open on Rise 

HTV 

10.0A 

6.0A 

6.0A 

1.0A

 

 

(38 to 116°C) 

(3 to 25°C) 

 

See page 416

 

 

 

 

 

11D31-1

100to240°F

7to45°F

SPDT

HH

7.4A

3.7A

2.9A

 

 

(38 to 116°C) 

(4 to 25°C) 

 

See page 416

HasU.L.approvedadjustabledialstop,factorysetat150°Fmaximum.

TYPES WITH BULBS DIRECTLY INTERCHANGEABLE WITH HONEYWELL (39/16” x 3/8”) No wells included.

SPDT Contact Structure

HH Rated Controls

Switch Action

R-B Open on Rise

R-W Close on Rise

 

 

 

 

 

Full 

Motor Rating 

Valves and

 

Model 

 

 

 

Switch 

Electrical 

(Full Load) 

Relays

  Number 

Range 

Differential 

Action 

Rating 

120 VAC 

240 VAC

 

24 VAC 

0.3-12v DC

 

1131-102  

100to240°F

7to45°F

SPDT

HH

7.4A

3.7A

2.9A

 

 

(38 to 116°C) 

(4 to 25°C) 

 

See page 416

 

 

 

 

 

11B18-101  ➀ 

100 to 240°F 

5 to 45°F 

Open on Rise 

HTV 

10.0A 

6.0A 

6.0A 

1.0A

 

 

(38 to 116°C) 

(3 to 25°C) 

 

See page 416

 

 

 

 

 

HasU.L.approvedadjustabledialstop,factorysetat150°Fmaximum.

TYPES WITH TAPERED BULBS (27/16” x 7/16”) All types include 1/2” standard shank well, unless otherwise specified.

CONTRACTOR TIP: 

TESTING AUTOMATIC TEMPERATURE CONTROLS To verify a control is opening and closing properly, disconnect 

all power before testing. Testing must be performed with the sensing element at a temperature within the setting range of the control. For 

mosthydroniccontrolswitharangeof100to240°F,apanofhotwaterissufficienttoreachthecontrolrange.

Attach an ohmmeter or continuity tester across the Open on Rise contacts. Lower the temperature setting dial to the lowest setting. 

If the lowest setting is below the temperature of the sensing element minus the differential of the control, the contacts should be open. 

Raise the temperature dial slowly. When the setting is raised above the temperature of the sensor, the contacts should close.

www.white-rodgers.com

106

HYDRONIC / APPLIANCE

Also See for White Rodgers 1131-102 Well Immersion Single Control

Related Manuals for White Rodgers 1131-102 Well Immersion Single Control