Whirlpool GU3600XTV User's Manual

Whirlpool Dishwasher User's Manual - GU3600XTV.
Download
Page  of 1
4.5, 1222 votes
background image

Undercounter Dishwasher

®

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

CABINET OPENING DIMENSIONS

GU3200XTS
GU3600XTS
GU3600XTV

Electrical: 120-volt, 60-Hz, AC-only, 15- or 
20-amp fused electrical supply. Use copper wire
only. A time-delay fuse or circuit breaker and
separate circuit is recommended.

Water: A hot water line with 20 to 120 psi 
(138 to 862 kPa) water pressure. Water temperature
must be 120°F (49°C) at dishwasher. Use 3/8" O.D.
copper tubing with compression fitting or flexible
stainless steel braided fill line (1/2" minimum plastic
tubing is optional but not recommended). Use a 90°
elbow with 3/8" N.P.T. external pipe threads on one
end to connect to water inlet valve. Do not solder
within 6" (15.2 cm) from water inlet valve.

Drain: Use the new drain hose supplied with your
dishwasher. If this is not suitable, use a new drain
hose with a maximum length of 12 feet (3.7 m) 
that meets all current AHAM/IAPMO test 
standards, is resistant to heat and detergent, and
fits the 1" (2.5 cm) drain connector of the
dishwasher. Connect drain hose to waste tee or
disposer inlet above drain trap in house plumbing
and 20" (50.8 cm) minimum above the floor. Use an
air gap if the drain hose is connected to house
plumbing lower than 20" (50.8 cm) above subfloor
or floor. Use 1/2" minimum I.D. drain line fittings.

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.

Ref. W10021230

10-30-08

25" (63.5 cm)

3/4" (1.9 cm)

insulation – may be

compressed (not used

on all models)

Side view

Rear view

21" (53.3 cm)

23-7/8" 

(60.6 cm)

33-7/8" 

(86 cm) min. with

wheels removed

Cut holes in shaded area of cabinet walls or floor as specified below:

water line – 1/2" (1.3 cm)

drain line – 1-1/2" (3.8 cm)

direct wire – 3/4" (1.9 cm)

power supply cord – 1-1/2" (3.8 cm)

* Measured from the lowest point on the underside of countertop. May be

reduced to 33-7/8" (86 cm) by removing wheels from dishwasher.

** Minimum, measured from narrowest point of opening.

*** May be increased to 6-5/8" (16.6 cm) if height of opening is 34-1/2" (87.6 cm)

at its lowest point.

9" 

(22.9 cm)

10" 

(25.4 cm)

6" ***

(15.2 cm)

6" ***

(15.2 cm)

3-1/4" 

(8.3 cm)

2-3/4"

(7 cm)

34" 

(86.4 cm)

min.*

2"

(5.1 cm)

2"

(5.1 cm)

All surfaces must be free

from intrusions

2"

(5.1 cm)

3-1/4" 

(8.3 cm)

3-1/4" 

(8.3 cm)

2-3/4"

(7 cm)

3-1/4" 

(8.3 cm)

24" (61 cm)

min.

24" (61 cm)

**

5-1/2" 

(14 cm)

3-1/2" 

(8.9 cm)

0.528892s