Whirlpool E1F50RD045V User's Manual | Page 10

Whirlpool Water Heater User's Manual - E1F50RD045V.
Download
Page  of 16
4.1, 2040 votes
background image

10

Adjusting the Thermostat/High Limit Control
This water heater is equipped with one or more adjustable temperature regulating thermostats and a manual reset high 
limit control. The following procedures must be performed when changing the temperature of the stored water or resetting 
the high limit control. Upper and lower thermostats must be adjusted to the same temperature.

IMPORTANT: Before attempting to adjust the thermostat, make sure you read the section of “Water Temperature 
Regulation” section. If the instructions are not clear, contact a qualifi ed person. 

1.   Disconnect the electric power.

2.   Remove the access cover(s) and fold up the insulation from the thermostat(s). Do not remove the plastic cover.

3.  Using a screwdriver to adjust the thermostat pointer, set the thermostat(s) to the desired water temperature.    

 

Be sure the RED reset button (High Limit Control) is pushed in. If needed, push in firmly to reset.

4.  Fold the insulation down, making sure the thermostat(s) are well covered. Replace the access cover(s).

5.   Reconnect power.

150°F

90°F

125°F

Optional

Door

Access

Cover

Thermostat / High Limit Control

Access
Covers

Red

Reset

Button

Thermostat

Pointer

Thermostat 

Setting

Double

Element

Heater

Single

Element

Heater

Figure 10
Thermostat

Insulation

(Shown Folded)

Insulation

(Shown Folded)

Insulation

(Shown Folded)

Related Manuals for Whirlpool E1F50RD045V