BLOWER PERFORMANCE - FG7TC/TL

FG7TC/TL - 95.1% AFUE, Two Stage Gas Furnace

Model Number

&

Heating Input

(Btuh)

Motor Switch Settings

(0 = OFF, 1 = ON)

External Static Pressure (in.W.C.)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

1/5

2/6

3/7

4/8

CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise

*TC / TL - 060D - 24B

(60,000)

0

0

0

0

1

0

0

0

0

1

0

0

1

1

0

0

725

0

0

1

0

810

1

0

1

0

940

56

890

59

845

795

750

700

0

1

1

0

990

53

945

56

905

58

860

820

775

735

690

1

1

1

0

1,055

50

1,015

52

970

54

930

57

890

59

845

805

760

0

0

0

1

1,135

47

1,095

48

1,055

50

1,010

52

960

55

930

57

890

59

850

1

0

0

1

1,185

45

1,145

46

1,105

48

1,065

50

1,030

51

990

53

950

56

910

58

0

1

0

1

1,250

42

1,210

44

1,170

45

1,135

47

1,095

48

1,055

50

1,020

52

980

54

1

1

0

1

1,290

41

1,255

42

1,220

43

1,180

45

1,145

46

1,110

48

1,075

49

1,040

51

0

0

1

1

1,315

40

1,275

41

1,240

43

1,200

44

1,160

45

1,120

47

1,085

49

1,045

51

1

0

1

1

1,350

39

1,315

40

1,280

41

1,245

42

1,205

44

1,170

45

1,135

47

1,100

48

0

1

1

1

1,390

38

1,350

39

1,315

40

1,275

41

1,240

43

1,200

44

1,160

45

1,125

47

1

1

1

1

1,420

37

1,380

38

1,345

39

1,310

40

1,270

42

1,235

43

1,200

44

1,160

45

*TC / TL - 80D - 35C

(80,000)

0

0

0

0

1,125

55

1,040

960

880

795

1

0

0

0

1,205

58

1,120

63

1,040

960

875

795

0

1

0

0

1,305

54

1,225

57

1,150

61

1,070

995

915

840

1

1

0

0

1,430

49

1,350

52

1,270

55

1,190

59

1,110

63

1,030

950

865

0

0

1

0

1,525

46

1,450

49

1,375

51

1,300

54

1,225

57

1,150

61

1,075

65

1,000

1

0

1

0

1,620

43

1,540

46

1,465

48

1,390

51

1,315

54

1,240

57

1,165

60

1,090

65

0

1

1

0

1,695

42

1,620

43

1,545

46

1,465

48

1,390

51

1,315

54

1,235

57

1,160

61

1

1

1

0

1,770

40

1,700

41

1,630

43

1,555

45

1,485

47

1,410

50

1,340

53

1,265

56

0

0

0

1

1,875

38

1,805

39

1,730

41

1,655

43

1,580

45

1,510

47

1,435

49

1,340

53

1

0

0

1

1,905

37

1,840

38

1,775

40

1,710

41

1,640

43

1,575

45

1,510

47

1,445

49

0

1

0

1

1,980

36

1,910

37

1,845

38

1,780

40

1,715

41

1,650

43

1,580

45

1,515

46

1

1

0

1

2,025

35

1,960

36

1,895

37

1,830

38

1,765

40

1,700

41

1,635

43

1,570

45

0

0

1

1

2,085

2,025

35

1,960

36

1,900

37

1,840

38

1,775

40

1,715

41

1,655

43

1

0

1

1

2,135

2,070

2,010

35

1,945

36

1,880

37

1,815

39

1,750

40

1,685

42

0

1

1

1

2,200

2,145

2,090

2,035

35

1,980

36

1,925

37

1,870

38

1,820

39

1

1

1

1

2,280

2,225

2,170

2,115

2,065

2,010

1,955

36

1,900

37

1.MotorSwitchSettingsareforheatingspeedsusingHEATswitches1,2,3,&4andcoolingspeedsusingCOOLswitches5,6,7,&8.
2.Twoopeningsarerecommendedforairflowsabove1,600CFMifthefilter(s)is(are)adjacenttothefurnace.
3.Dataisshownwithoutfilter.
4.Temperaturerisesinthetableareapproximate.Actualtemperaturerisesmayvary
5.Cellsshadedingrayindicateatemperatureriseoutsideoftherecommendedrange.
6.Wheninlowstage,thecirculatingairflowis70%ofthetableshighvalue(2-stagefurnacesonly).

0.631593s