Westinghouse FG7TC 95.1% AFUE Two-Stage Technical Literature | Page 4

Westinghouse Furnace Technical Literature - FG7TC 95.1% AFUE Two-Stage.
Download
Page  of 8
4.9, 1346 votes
background image

4

MODEL IDENTIFICATION CODE

DesignSeries

A=80%Upflow/Horizontal
C=92.1%/95.1%Upflow/Horizontal
K=80%Downflow
L=92.1%/95.1%Downflow
Q=97.0%AFUEUpflow/Horizontal

FG

T

080

D

24

Input Heating Capacity

060=60,000
080=80,000
100=100,000
120=120,000

S=SingleStage
T=TwoStage
M=Modulating

GasFurnace

C

C=Standard
D=90+%AFUELowNOx

Cooling Airflow

23=2-3Tons
24=2-4Tons
35=3-5Tons
45=4-5Tons
V=VSB

7

Cabinet Width

B=17.50
C=21.00
D=24.50

B

SPECIFICATIONS

*TL120is94.8%AFUE

Note:
Allmodelsare115V,60Hz.GasConnectionsare1/2"N.P.T.AFUE=AnnualFuelUtilizationEfficiency
(a)Ratingsto2,000ft.Over2,000ft.reduce4%foreach1,000ft.abovesealevel.

FG7TC/TL
MODELS NUMBERS:

-060D-24B

-080D-35C

-100D-35C

-120D-45D

Input-Btuh(a)

60,000/39,000

80,000/52,000

100,000/65,000 120,000/78,000

HeatingCapacity-Btuh

57,000/37,050

76,000/49,400

95,000/61,750

114,000/74,100

AFUE

95.1

95.1

95.1

95.1*

BlowerDxW

11x8

11x10

11x10

11x10

MotorH.P.-Speed-Type

1/2-BLDC

3/4-BLDC

3/4-BLDC

1-BLDC

MotorFLA

6.2

8.7

8.7

11.7

RatedExt.SP-In.W.C.

0.5

0.5

0.5

0.5

TemperatureRiseRange-ºF

30-60

35-65

35-65

40-70

ShippingWeights

125lbs

135lbs

145lbs

160lbs

0.605264s