Tyco Software House RM-DCM-CAN User's Manual
D A T A s h e e T
Input/Output Modules
Features That Make a Difference:
Provides cost-effective expansion of input and output capacity
Compatible with ful range of Software House® iSTAR and apC
access control panels
Locate modules up to 1,220 m (4,000 ft) away from control ers using
flexible two-wire RS-485 RM bus
Reduces length of sensor and control wiring to save instal ation
costs
I8 provides eight Class A supervised inputs
R8 provides eight Form C relay outputs
I8-CSI, configurable supervised input model, allows use of existing
input wiring without changing end-of-line (EOL) resistors
Three status LEDs per input (red/yel ow/green) and one per output
enable quick diagnostics and troubleshooting
Smal , modular size requires minimal panel space
Dedicated tamper input included on each module
Optional UL-listed enclosure available
The Software House I8, R8, and I8-CSI modules provide a
flexible, cost-effective means to expand the input and output
functionality of any iSTAR or apC access controller. Common
applications include alarm monitoring and control and elevator
control.
The I8 input module provides eight Class A supervised inputs.
Three LEDs per input help the installer commission and
troubleshoot each input circuit – red if the input is in alarm,
green for normal, and yel ow for a supervision error. LEDs may
be turned off via a DIP switch setting.
The I8-CSI module enhances the functionality of the standard
I8 module by supporting numerous supervised circuit types and
EOL resistance values. This al ows the I8-CSI to accommodate
existing field wiring without changing EOL resistors. More
than 20 different circuit types are supported. The circuit type
is selected via a bank of DIP switches and applies to all eight
inputs on the I8-CSI.
The R8 output module provides eight Form C dry contact relay
outputs. A red status LED per output shows the state of the
relay.
All modules feature a dedicated input for an external cabinet
tamper switch and mount easily in the Software House RM-CAN
or RM-DCM-CAN enclosure. The modules communicate with
iSTAR or apC control ers via the two-wire RM bus that al ows
total wiring distances of up to 1,220 m (4,000 ft). Up to eight I8s
and eight R8s can be connected to each apC, iSTAR eX, and
iSTAR Pro eight-reader model; up to 16 of each module can be
connected to the iSTAR Pro 16-reader model.
The modules are ful y compatible with both C•CURE® 800/8000
and C•CURE 9000.
Related Manuals for Tyco Software House RM-DCM-CAN
-
ADTRAN Network Card Total Access 5000 Command Reference Manual
1200 pages
-
Toshiba Network Card TOSVERT VF-S9 User's Manual
17 pages
-
TP-Link Network Card AV200 User's Manual
2 pages
-
TP-Link Network Card AV600 User's Manual
2 pages
-
Bose Network Card 802c User's Manual
20 pages
-
Trane Network Card CH530 User's Manual
36 pages
-
Honeywell Network Card Modutrol IV Motors Series 90 User's Manual
12 pages
-
Delta Electronics Network Card AC Drive VFD-F Series User's Manual
161 pages
-
Delta Electronics Network Card Programmable Logic Controller DVP28SV User's Manual
2 pages
-
ADTRAN Network Card NetVanta 818 User's Manual
2 pages
-
ADTRAN Network Card NetVanta 838 User's Manual
2 pages
-
ADTRAN Network Card OPTI-3 CPE User's Manual
2 pages
-
ADTRAN Network Card OPTI-6100 User's Manual
2 pages
-
ADTRAN Network Card Total Access 5000 User's Manual
2 pages
-
Siemens Network Card 6RA70 User's Manual
232 pages
-
M-Audio Network Card FireWire 410 User's Manual
30 pages
-
Alcatel-Lucent Network Card OmniVista 4760 User's Manual
11 pages
-
Datalogic Scanning Network Card Connection Box CBX100 User's Manual
2 pages
-
Tyco Network Card Software House RM-DCM-2 User's Manual
2 pages
-
MegaVision Network Card Network Management System User's Manual
62 pages
-
JDS Uniphase Network Card T-BERD 8000 User's Manual
2 pages
-
TP-Link Network Card TL-PA4010 User Guide
29 pages
-
LSI Network Card SAS3081E User's Manual
46 pages
-
LSI Network Card SAS3442E User's Manual
46 pages