D A T A   s h e e T

Input/Output Modules
Features That Make a Difference:

   Provides cost-effective expansion of input and output capacity 
   Compatible with ful  range of Software House® iSTAR and apC 

access control panels

   Locate modules up to 1,220 m (4,000 ft) away from control ers using 

flexible two-wire RS-485 RM bus

   Reduces length of sensor and control wiring to save instal ation 

costs

   I8 provides eight Class A supervised inputs
   R8 provides eight Form C relay outputs
   I8-CSI, configurable supervised input model, allows use of existing 

input wiring without changing end-of-line (EOL) resistors

   Three status LEDs per input (red/yel ow/green) and one per output 

enable quick diagnostics and troubleshooting

   Smal , modular size requires minimal panel space
   Dedicated tamper input included on each module
   Optional UL-listed enclosure available

The Software House I8, R8, and I8-CSI modules provide a 
flexible, cost-effective means to expand the input and output 
functionality of any iSTAR or apC access controller. Common 
applications include alarm monitoring and control and elevator 
control.

The I8 input module provides eight Class A supervised inputs. 
Three LEDs per input help the installer commission and 
troubleshoot each input circuit – red if the input is in alarm, 
green for normal, and yel ow for a supervision error. LEDs may 
be turned off via a DIP switch setting.

The I8-CSI module enhances the functionality of the standard 
I8 module by supporting numerous supervised circuit types and 
EOL resistance values. This al ows the I8-CSI to accommodate 
existing field wiring without changing EOL resistors. More 
than 20 different circuit types are supported. The circuit type 
is selected via a bank of DIP switches and applies to all eight 
inputs on the I8-CSI.

The R8 output module provides eight Form C dry contact relay 
outputs. A red status LED per output shows the state of the 
relay.

All modules feature a dedicated input for an external cabinet 
tamper switch and mount easily in the Software House RM-CAN 
or RM-DCM-CAN enclosure. The modules communicate with 
iSTAR or apC control ers via the two-wire RM bus that al ows 
total wiring distances of up to 1,220 m (4,000 ft). Up to eight I8s 
and eight R8s can be connected to each apC, iSTAR eX, and 
iSTAR Pro eight-reader model; up to 16 of each module can be 
connected to the iSTAR Pro 16-reader model. 

The modules are ful y compatible with both C•CURE® 800/8000 
and C•CURE 9000.