Trane XR 90 SERIES Owner's Manual | Page 6
6
22-1674-04-0803 (EN)
General
Data
Product Specifications 1
MODEL
TYPE
RATINGS 2
Input BTUH
Capacity BTUH (ICS) 3
AFUE (ICS)
Temp. rise (Min.-Max.) °F.
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGER
Type-Fired
-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
1 Central Furnace heating designs are certified by AGA and CSA.
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea
level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet
above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
TUX100C948D
Upflow / Horizontal
100,000
93,000
92.0
35 - 65
DIRECT
10 x 10
1
4
See Fan Performance Table
1/2
1075
115/1/60
Centrifugal
Direct - 1
1/20 - 3450
115/1/60
0.71
Yes
High Velocity
1 - 20x25 - 1in.
2 Round
Aluminized Steel - Type I
20
5 — 45
5 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
5
115/1/60
12.5
15
1/2
H x W x D
41-3/4 x 23 x 30-1/2
171 / 160
TUX120C960D
Upflow / Horizontal
120,000
113,000
92.0
40 - 70
DIRECT
11 x 10
1
4
See Fan Performance Table
3/4
1100
115/1/60
Centrifugal
Direct - 1
1/20 - 3450
115/1/60
0.71
Yes
High Velocity
1 - 24x25 - 1in.
3 Round
Aluminized Steel - Type I
20
6 — 45
6 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
6
115/1/60
12.9
15
1/2
H x W x D
41-3/4 x 26-1/2 x 30-1/2
205 / 193
TUX100C960D
Upflow / Horizontal
100,000
93,000
92.0
35 - 65
DIRECT
11 x 10
1
4
See Fan Performance Table
3/4
1100
115/1/60
Centrifugal
Direct - 1
1/20 - 3450
115/1/60
0.71
Yes
High Velocity
1 - 24x25 - 1in.
2 Round
Aluminized Steel - Type I
20
5 — 45
5 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
5
115/1/60
12.9
15
1/2
H x W x D
41-3/4 x 26-1/2 x 30-1/2
197 / 185
Related Manuals for Trane XR 90 SERIES
-
Bryant Furnace PLUS 90X 353AAV User's Manual
22 pages
-
Bryant Furnace 310AAV Service Manual
45 pages
-
Bryant Furnace 915SA Product data
16 pages
-
Bryant Furnace 350MAV User's Manual
12 pages
-
Bryant Furnace PLUS 95S 355CAV Owner's Manual
14 pages
-
Carrier Furnace WEATHERMAKER 8000 58ZAV Instruction Manual
24 pages
-
Coleman Furnace DGAA User's Manual
14 pages
-
Goodman Mfg Furnace GMS90453BXA Parts list
11 pages
-
Rheem Furnace CRITERION II Installation Manual
8 pages
-
Carrier Furnace 58GS User's Manual
12 pages
-
Carrier Furnace 58MCB User's Manual
12 pages
-
Rinnai Furnace ENERGYSAVER ES38 User's Manual
44 pages
-
Bryant Furnace Condensing s 398AAV User's Manual
12 pages
-
Thermo Products Furnace Thermo Pride Furnace OL6RA072D48(B/R) User's Manual
75 pages
-
Thermo Products Furnace OL5-85 User's Manual
32 pages
-
Thermo Products Furnace Thermo Pride Furnace MHA1-75N User's Manual
61 pages
-
Atwood Mobile Products Furnace HYDRO FLAME 8935 User's Manual
7 pages
-
Atwood Mobile Products Furnace HYDRO FLAME 8940 User's Manual
7 pages
-
Westinghouse Furnace FG7TC 95.1% AFUE Two-Stage Technical Literature
8 pages
-
Maytag Furnace PGC2TC PGC2TL | Maytag M1200 95.1% AFUE Two-Stage Fixed-Speed Gas Furnace Technical Literature
8 pages
-
Rinnai Furnace EX22C (RHFE-559FTA) Installation and Operation Manual
84 pages
-
York Furnace TM9Y Technical Guide
4 pages
-
York Furnace TM9E User's Manual
8 pages
-
GAMA Furnace Gas-Fired Furnace User's Information Manual
40 pages