background image

INSTALL WINDOW PANEL

Installation in a sliding sash window
(See page 10 for installation in a double-hung window.) 

Hole

Projection

Insect guard net

Rain guard

"A"

Window panel

Projection

"A"

Window 
panel

E-12

1 Connect the rain guards to the insect 

guard net.

 

Insert all three projections on each rain 

guard into the holes in the insect guard 
net.

 

Side “A” will now be at the top, as indicated 

in the diagram.  

2 Attach the guard combined above to the 

window panel. 

 

Push the insect guard net fi rmly to ensure 

that its four projections fi t into the holes in 
the window panel.

 

Side “A” will now be at the top, as indicated 

in the diagram, when it is installed in the 
window. 

3 Cut the foam seal A (adhesive type) to 

the proper length and attach it to the 
window frame.

4 Install the window panel into the window 

frame.

If the inner height of the window is 
between 22" (559mm) and 24" (609mm) 
inclusive. 

The window panel cannot be installed in 
windows less than 22" (559mm) high, as 
you will be unable to shut the exhaust 
cover.

(1)  Remove the adjustment panel from the 

window panel, and cut the window pan-
el to the same height as the window.

(2)  Open the window sash and place the 

window panel on the window frame.  

(3)  Secure the window panel to the window 

frame with 2 screws.

Cut

22"~24"

Foam seal A
(adhesive type)