Sanyo 36KHS72R User's Manual
System: 36KHS72R
Indoor/Outdoor: KHS3672R/CH3672R
Wall Mounted Heat Pump
Power
V/PH/Hz
230/208/1/60
Circuit Ampacity
Fuse Size, Max.
Compressor
No. used
R.L. Amps - L.R.
Crankcase Heater
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
No. Motors
CFM
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
No. Motors
CFM
Indoor Sound Rating
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Drain Connection Size
Refrigerant
Lbs. - R410a (outdoor unit)
Control
Connection
Line Length, Max (ft.)
Lift Difference, Max (ft.)
Line Size
Line Size
Dimensions
Indoor Unit
Outdoor Unit
Weight
Net
Shipping
Shipping Volume
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity
Sensible Capacity
Latent Capacity
SEER
Dehumidification
Amps
Power Inputs
Outdoor Sound Rating
Heating
Total Capacity
HSPF
(A) 15-35 Indoor-Outdoor
(A) 15-35 Indoor-Outdoor
General Data (at 230V)
1
(A) 16.4-17.5
(W) -
Propel er
18-7/64-1
DC Motor
(RPM) 8 - 830
(W) 1 - 90
15.9
(Pints/H) 10.0
(BTU/H) 31,400 (9,500-31,400)
(BTU/H) 18,760
(BTU/H) 12,640
(Uncrated) 14-9/16 x 59-1/16 x 9-7/16
(W) 3,750/3,750
Aluminum Fin & Copper Pipe
Slit Plate - Inner Riffeled
(in.) 3/8”
6.17
Split System Submittal Data
Electric Expansion Valve
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Approval:
Date:
Construction:
Unit #:
Drawing #:
2 - 14.1
(sq.ft.) 7.26
(lbs.) 72.8 143
(A) 17.9/19.8
(in. O.D. Discharge) 3/8”
(in. O.D. Suction) 5/8”
DC Rotary Inverter
(High) 1942
(A) 17.3
R410A
(in.) H x W x D
(Crated) 18-7/16 x 62-9/16 x 12-9/16
Indoor Outdoor
(cu.ft.) 8.4 13.0
Indoor Outdoor
(lbs.) 90.4 161
(dB-A) 52
Cross Flow
4-13/18 L46 - 1
3 & Auto
(RPM, High) 4 - 1273
(W) 1 - 50
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Riffeled
(in.) 3/8”
3 - 12.7
(sq.ft.) 3.23
(HI/Med/Lo) 830/710/590
(A) 0.5
(in.) 1-1/4”
(Hi) (dB-A) 48
Flare
165
50 (outdoor lower), 100 (outdoor higher)
(Uncrated) 30-23/32 x 37 x 13-3/8
(Crated) 34-31/32 x 39-31/32 x 16-3/32
9
(BTU/H) 36,400 (8,000-36,400)
Print Form
Related Manuals for Sanyo 36KHS72R
-
Carrier Air Conditioners 24ABB3 Owner's Manual
2 pages
-
Vicks Air Conditioners V1200 Owner's Manual
2 pages
-
Trane Air Conditioners XL15i Owner's Manual
6 pages
-
Oreck Air Conditioners AIR12GU Owner's Manual
48 pages
-
Hunter Air Conditioners 30200 Owner's Manual
8 pages
-
Heat Controller Air Conditioners InverterFlex Series Owner's Manual
15 pages
-
Heat Controller Air Conditioners Patriot 80 Series Owner's Manual
4 pages
-
De'Longhi Air Conditioners PAC A110 Owner's Manual
18 pages
-
Trane Air Conditioners XE1000 Owner's Manual
6 pages
-
Mitsubishi Air Conditioners R410A User's Manual
18 pages
-
Sharp Air Conditioners CV10NH - 10,000 BTU Portable Air Conditioner Installation Manual
60 pages
-
White Rodgers Air Conditioners 1F78 User's Manual
6 pages
-
Goldstar Air Conditioners GWHD5000 Owner's Manual
44 pages
-
Duracraft Air Conditioners AMD-8500E User's Manual
8 pages
-
Trane Air Conditioners RTAC 140-400 User's Manual
252 pages
-
Haier Air Conditioners Commercial Cool CPN10XCJ User's Manual
36 pages
-
Haier Air Conditioners HSU-09HV03/R2(SDB) User's Manual
27 pages
-
Carrier Air Conditioners 30GB User's Manual
12 pages
-
De'Longhi Air Conditioners pinguino pac ct90 User's Manual
14 pages
-
Comfort-Aire Air Conditioners Air Conditioner PAD-121 User's Manual
19 pages
-
Kul Air Conditioners KU32085 User's Manual
28 pages
-
Trane Air Conditioners XR14 User's Manual
6 pages
-
Frigidaire Air Conditioners FFRH0822R1 Installation Instructions
6 pages
-
Arctic King Air Conditioners WINDOW/WALL TYPE ROOM AIR CONDITIONER User's Manual
20 pages