System: 26THW72R 

Indoor/Outdoor: THW2672R/CH2672R

Ceiling Suspended Heat Pump

Power   

 

V/PH/Hz  

 

230/208/1/60

Circuit Ampacity
Fuse Size, Max.

Compressor
No. used
R.L. Amps  - L.R.

Outdoor Unit
Fan type  
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
No. Motors
CFM
F.L. Amps

Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size

Indoor Unit
Fan type  
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
No. Motors
CFM
Indoor Sound Rating
F.L. Amps

Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Drain Connection Size

Refrigerant
Lbs. - R410a (outdoor unit)
Control
Connection
Line Length, Max (ft.)
Lift Difference, Max (ft.)
Line Size
Line Size

Dimensions
Indoor Unit

Outdoor Unit

Weight
Net 
Shipping

Shipping Volume

Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity
Sensible Capacity
Latent Capacity
SEER
Dehumidification
Amps
Power Inputs
Outdoor Sound Rating

Heating
Total Capacity
HSPF

                      (A)                         15-30 Indoor-Outdoor

                       (A)                         15-30 Indoor-Outdoor

        General Data (at 230V)

1

                           (A)                                          12.9-17.5

  Propel er

18-7/64-1

DC Motor

                  (RPM)                                         8 - 800

             (W)                                              1 - 90

14.5

                           (Pints/H)                                    7.7

(BTU/H)        24,400 (9,500-24,400)

(BTU/H)                                14,330
(BTU/H)                                10,070

(Uncrated)                  7-17/16 x 51-3/16 x 26-3/8

             (W)                             2,880/2,880

Aluminum Fin & Copper Pipe

Slit Plate - Inner Riffeled

       (in.)                                               3/8”

4.19

Split System Submittal Data

Electric Expansion Valve

Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:

Approval:
Date:
Construction:
Unit #:
Drawing #:

1-15.9

            (sq.ft.)                                                7.26

(lbs.)          64                                           128

                          (A)                                    15.6/17.3

(in. O.D. Discharge)                       3/8”

(in. O.D. Suction)                        5/8”

DC Rotary Inverter

                  (High)                                               1765

                  (A)                                                   13.8

R410A

(in.)                                        H x W x D

(Crated)               9-7/16 x 54-19/32 x 31-1/16

Indoor                                   Outdoor

(cu.ft.)        8.9                                           13.0

Indoor                                   Outdoor

(lbs.)          75                                           148

             (dB-A)                                             49

Centrifugal

5-1/8 - 4

3 & Auto

                  (RPM, High)                                 4 - 1179

             (W)                                              1 - 31

Aluminum Plate Fin & Copper Tube

Slit Plate - Inner Riffeled

       (in.)                                                9/32”

3 - 14.9

            (sq.ft.)                                                 1.81

(HI/Med/Lo)                          550/490/460

                  (A)                                                   0.5

  (in.)                                               1-1/4”

             (Hi) (dB-A)                                                39

Flare

165

50 (outdoor lower), 100 (outdoor higher)

(Uncrated)                       30-23/32 x 37 x 13-3/8

(Crated)             34-31/32 x 39-31/32 x 16-3/32

10.3

(BTU/H)   30,800 (8,000-30,800)

Print Form