Rinnai RUR98i (REU-KBP3237FFUD-US) Specification Sheet

Rinnai Water Heater Specification Sheet - RUR98i (REU-KBP3237FFUD-US).
Download
Page  of 2
4.8, 1343 votes
background image

RUR98i-SP                         9/2014 

Type of Appliance 

 
Rinnai model number 

Operation / Installation 

                                                                         
Minimum/Maximum Gas Rate (Input) 

Electrical 

 
Electrical Consumption 

Amperage  

 

Ignition System 

Hot Water Capacity 

 
 
Temperature 

 
                                                                           
Temperature (without remote)  

Approved Gas Types 

Energy Factor (EF) 

Service Connections 

 
 
Isolation & Pressure Relief Valves Included 
 

Water Flow Control 

Minimum/Maximum Water Supply Pressure 

Condensing, Tankless, Temperature controlled, continuous flow, gas hot 
water system with built in recirc pump, Energy Star Qualified 

REU-KBP3237FFUD-US 

Forced combustion; indoor only; Certified for instal ation in Manufactured 
(Mobile) Homes 

15,200 - 199,000 BTU/h (4.5-58.3 kW) 

Appliance: 

 

 

AC 120 Volts - 60 Hz 

Temperature Controller:   

DC 12 Volts 

Normal: 205 w   Standby: 3 w   Anti-frost protection: 150 w 

Max: 8A Fuse: 10A 

Direct electronic ignition 

Minimum flow rate: 0.26 GPM (1 l/min) 
Minimum activation flow rate: 0.4 GPM 1.5 l/min) 
Maximum flow rate: 9.8 GPM (37.1 l/min) 

98° - 120° F (37°- 49°C) (factory default)  Maximum temperature is 
selectable at 120° F (49°C) or at 140° F (60°C);   

                                                                                                                                                                                                                             
120° F (49°C) (factory default) or 140° F (60°C) 

Natural or Propane (ensure unit matches gas type) 

Natural Gas: 0.95 

Propane: 0.95 

Gas supply: 3/4 inch (19mm) MNPT 
Cold water inlet: 3/4 inch (19mm) MNPT 
Hot water outlet: 3/4 inch (19mm) MNPT 

Heavy duty forged brass Isolation valves EXP E2, certified to NSF/ANSI 61-
8 for potable water 

Water flow sensor, electronic water control and by-pass control  

50 - 150 PSI (345-1035 KPa) (60 - 80 PSI (414 - 552 KPa) or above is 
recommended for maximum flow) 

RUR98i (KBP3237FFUD)  

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior 
notice. Local, state, provincial and federal codes must be adhered to prior to installation. 

FLOW TABLE 

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

0

25

50

75

100

125

150

kA3237

W

at

e

r Fl

o

w

 g

p

m

 (l/m

in

delta T - Temperature Rise ºF (ºC) 

 

(37.9)  

10.0  

(34.1)  

(11.4)  

 (7.6)  

 (3.8)  

(26.5)  

(30.3)  

(19.0)  

(22.7)  

(15.1)  

0.0 

9.0 

8.0 

2.0 

1.0 

6.0 

7.0 

4.0 

5.0 

3.0 

25 (13.9)  

50 (27.8)  

75 (41.6)  

100 (55.6)   125 (69.4)   150 (83.3)  

© 2014 Rinnai America Corporation 

Related Manuals for Rinnai RUR98i (REU-KBP3237FFUD-US)