Rinnai RUR98i (REU-KBP3237FFUD-US) Operation and Installation Manual | Page 10

Rinnai Water Heater Operation and Installation Manual - RUR98i (REU-KBP3237FFUD-US).
Download
Page  of 61
4.8, 1878 votes
background image

10 

KBP Series Manual 

 

Unit clearances 

Indoor             

model    

RUR98i 

to Combustibles 

inches (mm)  

 

to Non-

Combustibles 

inches (mm)     

Top of Heater 

6 * (152) 

2 *(51) 

Back of Heater 

0 (zero) 

0 (zero) 

Front of Heater 

6 (152) 

6 (152) 

Sides of Heater 

2 (51) 

1/2 (13) 

Ground/Bottom 

12 (305) 

12 (305) 

Vent 

0 (zero) 

0 (zero) 

* 0 inches from vent components and condensate drain 
line. 

The clearance for servicing is 24 inches in front of the 
water heater. 

For closet installation, clearance is 6 inches (152 mm from 
the front.   

Outdoor 

model  

RUR98e 

to Combustibles 

inches (mm)  

 

to Non-

Combustibles 

inches (mm)     

Top of Heater 

12 (305) 

2 (51) 

Back of Heater 

0 (zero) 

0 (zero) 

Front (panel) 

24 (610) 

0 (zero) 

Front (exhaust) 

24 (610) 

24 (610) 

Sides of Heater 

6 (152) 

1/8 (3.2) 

Ground/Bottom 

12 (305) 

2 (51) 

The clearance for servicing is 24 inches in front of the 
water heater. 

to side

to front

to top

to floor/ground

Freeze Protection 

Make sure that in case of freezing weather the water 
heater and its water lines are protected to prevent 
freezing.  Damage due to freezing is not covered by 
the warranty. 

Loss of freeze protection may result in water damage 
from a burst heat exchanger or water lines.   

With electrical power supplied, the water heater will 
not freeze when the outside air temperature is as cold 
as –22°F (-30°C) for indoor models or is as cold as –4°F 
(-20°C) for outdoor models, when protected from 
direct wind exposure.  Because of the “wind-chill” 
effect, any wind or circulation of the air on the unit 
will reduce its ability to freeze protect. 

The unit may be drained manually.  However, it is 
highly recommended that: 

  drain down solenoid valves be purchased and 

installed that will automatically drain the unit if 
power is lost.   These are available in a kit, 
104000059.  (The condensate trap drain plug, 
water drain plug, and pump drain plug are not 
affected by the auto drain down solenoid valves 
and will have to be manually opened.) 

  a surge protector with terminals be purchased 

and installed which allows the solenoid valves to 
operate if the unit is disabled due to a diagnostic 
code.  This is available as 104000057. 

In addition, the solenoid valves should be connected 
electrically to a surge protector with terminals.  This 
allows the solenoid valves to operate if the water 
heater is disabled due to a diagnostic code.   

The freeze protection features will not prevent the 
external piping from freezing.  It is recommended that 
hot and cold water pipes be insulated.  Pipe cover 
enclosures may be packed with insulation for added 
freeze protection. 

It is recommended that the condensate trap drain line 
be insulated.  A frozen condensate trap drain line 
results in diagnostic code 25. 

In the event of a power failure at temperatures below 
freezing, the water heater should be drained of all 
water to prevent freezing damage.  In addition, drain 
the condensate trap, drain line, and pump drain. 

 