Rinnai RUC98i (REU-KBD3237FFUD) Operation and Installation Manual | Page 7

Rinnai Water Heater Operation and Installation Manual - RUC98i (REU-KBD3237FFUD).
Download
Page  of 140
4.7, 1684 votes
background image

 

KBD Series Manual 

 

    INSIDE
CORNER DETAIL

FIXED
CLOSED

OPERABLE

FIXED
CLOSED

OPERABLE

B

B

B

A

J

B

M

C

F

B

B

E

D

L

G

A

H

K

I

[1]  A vent shall not terminate directly above a sidewalk or paved driveway 

that is located between two single family dwellings and serves both 
dwellings. 

[2]  Permitted only if veranda, porch, deck, or balcony is fully open on a 

minimum of two sides beneath the floor. 

  For clearances not specified in ANSI Z223.1/NFPA 54, clearances are in 

accordance with local installation codes and the requirements of the gas 
supplier. 

  Clearance to opposite wall is 24 inches (60 cm). 

X

V

AIR SUPPLY INLET 

VENT TERMINAL 

AREA WHERE TERMINAL 
IS NOT PERMITTTED 

For indoor models, you must install a vent termination to bring in combustion air and expel exhaust to the outside. 

SNOW

TERMINATION

Clearance in
Ref. A also
applies to
anticipated
snow line

Ref 

Description 

Canadian Installations 

US Installations 

Clearance above grade, veranda, porch, deck, or balcony 

12 inches (30 cm) 

12 inches (30 cm) 

Clearance to window or door that may be opened 

36 inches (91 cm) 

12 inches (30 cm) 

Clearance to permanently closed window 

Vertical clearance to ventilated soffit, located above the terminal within 
a horizontal distance of 2 feet (61 cm) from the center line of the 
terminal 

Clearance to unventilated soffit 

Clearance to outside corner 

Clearance to inside corner 

Clearance to each side of center line extended above meter/regulator 
assembly 

3 feet (91 cm) within a height 15 

feet (4.5 m) above the meter/

Clearance to service regulator vent outlet 

36 inches (91 cm) 

Clearance to nonmechanical air supply inlet to building or the 
combustion air inlet to any other appliance 

36 inches (91 cm) 

12 inches (30 cm) 

Clearance to a mechanical air supply inlet 

6 feet (1.83 m) 

3 feet (91 cm) above if within 10 

Clearance above paved sidewalk or paved driveway located on public 
property 

7 feet (2.13 m)  

Clearance under veranda, porch, deck, or balcony  

12 inches (30 cm)   

Direct Vent Terminal Clearances (Indoor Units) 