Rinnai RL94i (REU-VC2837FFUD-US) Specification Sheet

Rinnai Water Heater Specification Sheet - RL94i (REU-VC2837FFUD-US).
Download
Page  of 2
4.9, 1705 votes
background image

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

0

25

50

75

100

125

150

Water Flow

 (gpm) 

delta T - Temperature Rise (ºF) 

Type of Appliance 

 
 
 
Rinnai Model Number 

Minimum/Maximum Gas Rate (Input) 

Electrical 

 
Electrical Consumption 

Ignition System 

Hot Water Capacity 

 
 
Temperature 

 
 
Temperature (without remote)  

Installation 

Energy Factor 

Service Connections 

 
Isolation & Pressure Relief Valves Included 
 

Water Flow Control 

Minimum/Maximum Water Supply Pressure 

•  Temperature controlled, continuous flow, gas hot water system 

•  Certified for installation in manufactured (mobile) homes 
•  Forced combustion / Direct vent 
•  Energy Star qualified 

REU-VC2837FFUD-US 

10,300 - 199,000 BTU/h  

Appliance: 

 

 

AC 120 Volts - 60 Hz 

Controller: 

  DC 

12 

Volts 

Normal:  97 w  Standby:  2 w  Anti-frost protection:  120 w 

Direct electronic ignition 

Minimum flow rate: 0.26 GPM 
Minimum activation flow rate: 0.4 GPM 
Maximum flow rate: 9.8 GPM 

98° - 120° F  (factory default)  Maximum temperature is selectable at 
120° F or at 140° F;  98° - 185° F available with the MCC-91-2 
controller for commercial and hydronic applications 

120° F (factory default) or 140° F 

Indoor only 

Natural Gas: 0.82 

 

Propane: 0.82 

Gas supply: 3/4 inch MNPT 

Cold water inlet: 3/4 inch MNPT 

Hot water outlet: 3/4 inch MNPT 

Heavy duty forged brass Webstone Isolator valves EXP E2, certified 
to NSF/ANSI 61-8 for potable water 

Water flow sensor, electronic water control device and by-pass 

20 - 150 PSI (recommended 30-80 PSI for maximum performance) 

© 2012 Rinnai Corporation 

RL94i VC SP                         3/2012 

FLOW TABLE 

RL94i (VC2837FFUD-US)    

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior 
notice. Local, state, provincial and federal codes must be adhered to prior to installation. 