Rinnai EX17C (RHFE-434FTA) Specification Sheet
restarts automatically when ignition or combustion fails
starts and turns off the heater at 2 timer settings
provides precise gas flow by operating from one to seven stages
detects temperature change in 1/2 of a degree
monitors and controls combustion fan and allows the appliance to
overcome winds of up to 40 mph
continually monitors functions; provides auto shutdown codes; indicates
when air filter needs cleaning
reduces noise through use of swept blades in convection fan; quiet
expansion / contraction of parts due to temperature changes
Restart capability:
Timer Settings:
Seven-stage modulating gas valve:
Negative coefficient thermistor:
Variable speed inducer motor with
pressure switch:
Self diagnostic electronics:
Quiet operation:
EX17C (RHFE-434FTA)
Type of Appliance
Rinnai Model Number
Gas Rate Input (BTU/hour)
Gas Rate Output (BTU/hour)
AFUE Rating
Minimum Gas Supply Pressure
Maximum Gas Supply Pressure
Electrical Connection
Gas Connection
Combustion System
Ignition System
Fan CFM Output
Temperature Settings
Temperature Control
Humidifier Tray
Weight
Clearance from Combustibles
Noise Level
Warm Air Outlet
Direct vent wall furnace suitable for homes, apartments, and
condominiums, residential or commercial setting; modular/mobile home
approved; forced combustion, forced convection
RHFE-434FTA-A-N (Natural gas) RHFE-434FTA-A-P (Propane)
Low - 8,200
Low - 8,200
High - 16,700
High - 16,700
Low - 6,560
Low - 6,560
High - 13,360
High - 13,360
81%
82%
3.5 in (89 mm) W.C.
8 in (203 mm) W.C.
10.5 in (267 mm) W.C
13 in (330 mm) W.C.
AC 120V, 60 Hz, 46 watts
1/2 inch NPT
Stainless steel Bunsen burners
Electronic spark ignition
Low: 110.5
High: 141.3
Low (LO): minimum combustion
60° - 80° F in 2° increments
High (HI): maximum combustion
• Electronic thermostat
• Temperature limiting program to comply with Inside Design
Temperature limits
Enameled tray with capacity of 2.1 pints (1000 cc)
Approximately 57 lbs (26 kg)
Side: 2 inches (50 mm), Top: 0 inches (0 mm), Front: 40 inches (1 m)
33 - 38 dB(A)
Bottom front louvers
© 2011 Rinnai Corporation
RHFE-434FTA SP 6/2011
FEATURES
Also See for Rinnai EX17C (RHFE-434FTA)
Related Manuals for Rinnai EX17C (RHFE-434FTA)
-
Bryant Furnace PLUS 90X 353AAV User's Manual
22 pages
-
Bryant Furnace 310AAV Service Manual
45 pages
-
Bryant Furnace 915SA Product data
16 pages
-
Bryant Furnace 350MAV User's Manual
12 pages
-
Bryant Furnace PLUS 95S 355CAV Owner's Manual
14 pages
-
Carrier Furnace WEATHERMAKER 8000 58ZAV Instruction Manual
24 pages
-
Coleman Furnace DGAA User's Manual
14 pages
-
Goodman Mfg Furnace GMS90453BXA Parts list
11 pages
-
Rheem Furnace CRITERION II Installation Manual
8 pages
-
Trane Furnace XR 90 SERIES Owner's Manual
16 pages
-
Carrier Furnace 58GS User's Manual
12 pages
-
Carrier Furnace 58MCB User's Manual
12 pages
-
Rinnai Furnace ENERGYSAVER ES38 User's Manual
44 pages
-
Bryant Furnace Condensing s 398AAV User's Manual
12 pages
-
Thermo Products Furnace Thermo Pride Furnace OL6RA072D48(B/R) User's Manual
75 pages
-
Thermo Products Furnace OL5-85 User's Manual
32 pages
-
Thermo Products Furnace Thermo Pride Furnace MHA1-75N User's Manual
61 pages
-
Atwood Mobile Products Furnace HYDRO FLAME 8940 User's Manual
7 pages
-
Westinghouse Furnace FG7TC 95.1% AFUE Two-Stage Technical Literature
8 pages
-
Maytag Furnace PGC2TC PGC2TL | Maytag M1200 95.1% AFUE Two-Stage Fixed-Speed Gas Furnace Technical Literature
8 pages
-
Rinnai Furnace EX22C (RHFE-559FTA) Installation and Operation Manual
84 pages
-
York Furnace TM9Y Technical Guide
4 pages
-
York Furnace TM9E User's Manual
8 pages
-
GAMA Furnace Gas-Fired Furnace User's Information Manual
40 pages