Rheem Professional Classic Series: Heavy Duty Specification Sheet

Rheem Water Heater Specification Sheet - Professional Classic Series: Heavy Duty.
Download
Page  of 1
4.4, 1775 votes
background image

PRINTED IN U.S.A. 01/14 WP FORM NO. PROG RHHDCAN

INTEGRATED HOME COMFORT

INTEGRATED HOME COMFORT

Professional Classic™ Heavy Duty 

gas water heaters exceed ANSI standards 

for flammable vapor ignition resistance

Efficiency
•  .53 - .57 EF
Performance
•  FHR: Up to 141 gallons for natural 

gas, up to 109 gallons for LP gas 

•  Recovery: Up to 75.8 gallons for 

 natural gas, up to 67.7 gallons for LP 

gas at a 90 degree rise

Guardian System™ & Sensor
•  Exclusive air/fuel shut-off device
•  Maintenance free – no filter to clean
•  Disables the heater in the presence of 

flammable vapor accumulation

Self-Cleaning
•  60-gallon models only
•  EverKleen™ patented system fights 

sediment build-up

• Reduces fuel costs
• Fights sediment build-up
Easy to Light
•  Piezo Ignitor – no matches required
Low Emissions
•  Eco-friendly burner, low NOx design
•  Meets 40 ng/J NOx  requirements

Longer Life
•  Rheem exclusive R-Tech (resistored) 

anode rod provides long-lasting tank 

protection

High Altitude Compliant
•  All models are certified for  applications 

up to 7,700 feet above sea level

Plus…
•  Enhanced-flow brass drain valve 
•  Temperature and pressure relief valve 

included

• Low lead compliant
•  Side water connections for space 

heating applications for 75-gallon 

models

•  Standard replacement parts
Warranty
•  6-Year limited tank and parts warranty*
* See Residential Warranty Certificate for  

complete information

Professional Classic

Heavy Duty

60 and 75-Gallon Capacities

Up to 75,100 Btu/h

Natural and LP Gas

Flame Arrestor Plate

Combustion Shut-off System

  Water 

INTEGRATED HOME COMFORT

Residential Gas
Professional Classic 
Heavy Duty Water Heaters

Specify LP gas when ordering.  Add gas input and "P" to model number.  Example: PROG60S-50P CN56
† Complies with BC construction requirements.

 

 

 

DESCRIPTION 

FEATURES 

ROUGHING IN DIMENSIONS (SHOWN IN INCHES) 

ENERGY INFO.

  T 

 

 

 

 

 

 

 

 

HT. TO 

 

WATER 

HT. TO 

WATER 

 

 

 

 

  Y                

GAS INPUT IN 

RECOVERY IN 

 FIRST HOUR

 

HT. TO 

TANK 

 

GAS  

VENT 

CONN. 

SIDE T&P 

CONN. 

SHIP. 

 ENERGY 

  P  GAL. MODEL 

THOUS. BTU/H 

G.P.H. 90° RISE 

DEL. G.P.H.

  VENT  HT.  DIAM. CONN.  SIZE  CNTR.  VALVE  SIZE WT. 

FACTOR

  E 

CAP.  NUMBER 

NAT. 

 LP 

NAT. 

  LP 

NAT. 

LP 

(LBS) 

NAT.

 

Tall 

60 

PROG60S-50N 

CN56 

50  50  50.5 

50.5 

107 

107 62 58 23 13-1/4 4  8 48-1/2 3/4  180 

0.56

  Tall  60  PROG60S-50N CN57† 

50 

50 

50.5 

50.5 

107 

107 

62 

58 

22-1/4  13-1/4 

48-1/2 

3/4 

180 

0.57

  Tall  75  PROG75S-75N CN53 

75.1 

65 

75.8 

67.7 

141 

109 

64 

60 

26-1/4  14-3/4 

11 

53-1/4 

320 

0.53 

   In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.

Rheem Canada Ltd./Ltée  •  125 Edgeware Road, Unit 1 

Brampton, Ontario L6Y 0P5  •  www.rheem.com

E

G

B

A

C

F

H

HOT

WATER

CONNECTION

H

COLD

WATER

CONNECTION

D

1/2"

3/4" N.P.T.

RELIEF

VALVE

OPENING

FLUE

ANODE ROD

SIDE TAPS

(48, 63, 75

& 98 GAL.

MODELS 

ONLY)

SIDE TAPS ON

48, 63, 75 & 98 GAL. MODELS ONLY

Also See for Rheem Professional Classic Series: Heavy Duty

Related Manuals for Rheem Professional Classic Series: Heavy Duty

0.706515s