Rheem Prestige Series: Up to 96% AFUE Modulating ECM Motor Sales Fact Sheet
SALES FACT SHEET
RGFG- SERIES
Models with Input Rates
from 60 to 120 kBTU
[17.58 to 35.16 kW]
(All Models 95% A.F.U.E. or Above)
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable period
stated, in accordance with the terms of the limited warranty.
Primary and Secondary Heat Exchanger ............Limited Lifetime
Conditional Unit Replacement*
(Registration Required)......................................Limited Lifetime
Parts..................................................................Ten (10) Years
*See Product Warranty Card for Details.
Rheem Heating, Cooling and Water Heating
FORM NO. G11-522-SFS REV. 1
P.O. Box 17010, Fort Smith, AR 72917
PRINTED IN U.S.A.
QG
5-13
MODEL
RGFG
INPUT-MAX.
BTU/HR [kW]
INPUT-MIN.
BTU/HR [kW]
HEATING
CFM MAX.
W.C. E.S.P.
[L/s]
HEATING
CFM MIN.
W.C. E.S.P.
[L/s]
COOLING
CFM RANGE
W.C. E.S.P. [L/s]
CABINET
WIDTH
VENT
CONN.
SIZE
APPROX.
SHIPPING
WEIGHT
(LBS.) [kg]
PRICE
06EMCK
60,000 [17.58] 24,000 [7.03]
795 [375]
320 [151]
600-1200 [283-566] 17 1/2"
2
127 [57.6]
07EMCK
75,000 [21.98] 30,000 [8.79]
995 [470]
430 [203]
600-1200 [283-566] 17 1/2"
2
133 [60.3]
09EZCM
90,000 [26.38] 36,000 [10.55] 1195 [564]
515 [243]
1200-2000 [566-944]
21"
2
158 [71.7]
10EZCM 105,000 [30.77] 42,000 [12.31] 1395 [658]
600 [283]
1200-2000 [566-944]
21"
2
162 [73.5]
12ERCM 120,000 [35.17] 48,000 [14.07] 1595 [753]
685 [323]
1200-2000 [566-944]
24"
2
170 [77.1]
Minimum 95% A.F.U.E.
Communicating & Modulating
Upflow Gas Furnace Equipped with
the
Comfort Control 2 System™
and
Contour Comfort Control ®
Features
n The Comfort Control 2 System™ provides 28 on-board diagnostic codes
and fault history codes by detecting system and electrical problems.
“Call for Service” alert notification is sent to the thermostat to alert the
homeowner of required service.
n Serial Communication Enhanced – When installed with a Serial
Communicating Condensing Unit and user interface control
(RHC-TST550CMMS) 500 Series thermostat this unit offers 4 or 2 wire
installation, auto-configuration, and diagnostic messaging with full
communicating capability.
n Primary heat exchanger is constructed of all aluminized steel for
maximum corrosion resistance and thermal fatigue reliability.
n Modulating Function: when used with a modulating or communicating
thermostat, modulation rate between 40% and 100% of total capacity.
n Two-stage Function: when used with a two-stage thermostat, furnace
operates at 40% on first stage, and stages up to 65%, then 100% for
second stage.
n Multistage Function: when used with a single-stage thermostat, furnace
operates at 40%, 65% and 100% of total capacity.
n Reduced firing rates, electrically efficient ECM2+ motor, and solid doors
provide the ultimate in quiet operation.
n Low speed constant fan.
n Constant temperature rise for superior comfort.
n Seven segment LED for system diagnostics.
n Diagnostic history for troubleshooting.
n Variable speed induced draft motor.
n Direct spark ignition with remote sense.
n Optional indoor or outdoor combustion air.
• Serial communication enabled
• Increased system reliability and efficiency
• 28 on-board diagnostic and operating codes
• Active Protection™ with homeowner
“Call for Service” alert
• Dual 7-segment LED display
Also See for Rheem Prestige Series: Up to 96% AFUE Modulating ECM Motor
- Rheem Prestige Series: Up to 96% AFUE Modulating ECM Motor Product Literature 4 pages
- Rheem Prestige Series: Up to 96% AFUE Modulating ECM Motor Specification Sheet 12 pages
- Rheem Prestige Series: Up to 96% AFUE Modulating ECM Motor Submittal Sheet 3 pages
- Rheem Prestige Series: Up to 96% AFUE Modulating ECM Motor Tax Credit Form 1 pages
- Rheem Prestige Series: Up to 96% AFUE Modulating ECM Motor Product Literature 4 pages
- Rheem Prestige Series: Up to 96% AFUE Modulating ECM Motor Sales Fact Sheet 2 pages
Related Manuals for Rheem Prestige Series: Up to 96% AFUE Modulating ECM Motor
-
Bryant Furnace PLUS 90X 353AAV User's Manual
22 pages
-
Bryant Furnace 310AAV Service Manual
45 pages
-
Bryant Furnace 915SA Product data
16 pages
-
Bryant Furnace 350MAV User's Manual
12 pages
-
Bryant Furnace PLUS 95S 355CAV Owner's Manual
14 pages
-
Carrier Furnace WEATHERMAKER 8000 58ZAV Instruction Manual
24 pages
-
Coleman Furnace DGAA User's Manual
14 pages
-
Goodman Mfg Furnace GMS90453BXA Parts list
11 pages
-
Rheem Furnace CRITERION II Installation Manual
8 pages
-
Trane Furnace XR 90 SERIES Owner's Manual
16 pages
-
Carrier Furnace 58GS User's Manual
12 pages
-
Carrier Furnace 58MCB User's Manual
12 pages
-
Rinnai Furnace ENERGYSAVER ES38 User's Manual
44 pages
-
Bryant Furnace Condensing s 398AAV User's Manual
12 pages
-
Thermo Products Furnace Thermo Pride Furnace OL6RA072D48(B/R) User's Manual
75 pages
-
Thermo Products Furnace OL5-85 User's Manual
32 pages
-
Thermo Products Furnace Thermo Pride Furnace MHA1-75N User's Manual
61 pages
-
Atwood Mobile Products Furnace HYDRO FLAME 8940 User's Manual
7 pages
-
Westinghouse Furnace FG7TC 95.1% AFUE Two-Stage Technical Literature
8 pages
-
Maytag Furnace PGC2TC PGC2TL | Maytag M1200 95.1% AFUE Two-Stage Fixed-Speed Gas Furnace Technical Literature
8 pages
-
Rinnai Furnace EX22C (RHFE-559FTA) Installation and Operation Manual
84 pages
-
York Furnace TM9Y Technical Guide
4 pages
-
York Furnace TM9E User's Manual
8 pages
-
GAMA Furnace Gas-Fired Furnace User's Information Manual
40 pages