If high efficiency filters or electronic air
cleaners are used in the system, it is
important that the airflow is not
reduced to maximize system
performance and life. Always verify
that the system’s airflow is not
impaired by the filtering system that
has been installed, by performing a
temperature rise and temperature drop
test.

Keep the filter(s) clean at all times.
Vacuum dirt from filter, wash with
detergent and water, air dry thoroughly
and reinstall.

DO NOT DOUBLE FILTER THE
RETURN AIR DUCT SYSTEM. DO
NOT FILTER THE SUPPLY AIR DUCT
SYSTEM.

RECOMMENDED ROUTINE
MAINTENANCE

1. It is recommended that an annual

inspection of your furnace, supply,
return drain, gas and vent systems
be done by a qualified installer,
service agency or the gas supplier.

2. Gas burners should be inspected

for dirt, rust, or scale and cleaned
or replaced as necessary.

LUBRICATION

The blower motor and induced draft
motor are prelubricated by the
component manufacturers and do not
require further attention. Addition of
lubricants can reduce the motor life
and void the warranty.

CONDENSATE

Be sure the vented condensate drain
line from the furnace is not connected
to the evaporator drain line and does
not become blocked or plugged. Visual
inspection of condensate flow can be
made after 10 minutes of furnace
operation. Condensate from the
furnace must flow freely.

If a neutralizer kit is required for the
condensate water from the furnace by
local codes it should be installed
according to the I & O manual.

Thank you for purchasing our product.

ADS-5422-01

FIGURE 8
UPFLOW BOTTOM FILTER INSTALLATION

I332

FIGURE 7
UPFLOW SIDE FILTER LOCATION

JACKET

FILTER

FILTER
ROD

FILTER
ROD

FILTER

JACKET ASSEMBLY

FILTER ROD
SUPPORT
ANGLE

FILTER
SUPPORT
ANGLE

TABLE 1
FILTER SIZES

UPFLOW FILTER SIZES

FURNACE

INPUT

BOTTOM

SIDE

QUANTITY

WIDTH

MBTUH

SIZE

SIZE

171/2"

45, 60, 75A

153/4" X 25"

153/4" X 25"

1

21"

75B, 90, 105

191/4" X 25"

153/4" X 25"

1

241/2"

120

223/4" X 25"

153/4" X 25"

1