Rheem Classic Series: 80% AFUE Single-Stage PSC Motor Submittal Sheet | Page 2

Rheem Furnace Submittal Sheet - Classic Series: 80% AFUE Single-Stage PSC Motor.
Download
Page  of 3
4.6, 2490 votes
background image

FORM NO. X33-1388 REV. 1

Supersedes X33-1155 Rev. 3

JOB NAME

MODEL NO.

CONTRACTOR

OUTDOOR UNIT MODEL NO.

ENGINEER

LOCATION

SUBMITTED FOR

APPROVAL

RECORD

ORDER NO.

DATE

UNIT DATA

HEATING PERFORMANCE

TOTAL CAPACITY INPUT* ...... _______ MBH [kW]

TOTAL CAPACITY OUTPUT* .. _______ MBH [kW]

DESIGN TEMP. RISE .............. _______ °F [°C] DB

AFUE ................................................ _______ %

CALIFORNIA SEASONAL

EFFICIENCY .................................. _______ %

(*uses blower motor heat)

SUPPLY AIR BLOWER PERFORMANCE

TOTAL AIR SUPPLY ................ _______ CFM [L/s] 

TOTAL RESISTANCE EXTERNAL

TO UNIT ...................................... _______ IWG

BLOWER SPEED .......................... _______ RPM

POWER OUTPUT REQUIREMENT .. _______ BHP

MOTOR RATING ........................ _______ HP [W]

POWER INPUT REQUIREMENT ........ _______ kW

ELECTRICAL DATA

POWER SUPPLY...................... ____________ Hz

TOTAL UNIT AMPACITY................ _______ AMPS

MINIMUM WIRE SIZE .................... _______ AWG

MAXIMUM OVERCURRENT DEVICE

FUSES/HACR BREAKER .......... _______ AMPS

FEATURES FOR RGPN-

• Innovative combustion design results in reliable, efficient

operation at sound levels which provide distinct competitive
advantage.

• Patented heat exchanger, constructed of aluminized steel for the

maximum in corrosion resistance and thermal fatigue reliability.

• Low profile “34 inch” design is lighter and easier to handle, and

leaves room for optional equipment.

• Convertible from upflow to horizontal left or right field conversion.
• Left or right side gas and electric inlet connections with quick,

simple change.

• Robust and reliable direct spark ignition utilizing remote sense

and an integrated board with humidifier and electronic air
cleaner hookups.

• Insulated blower compartment helps to reduce jacket loss and

noise.

• Pre-paint galvanized steel cabinet.
• Molded permanent filter.
• Grab-holes in doors to aid in easy door removal and

 replacement.

✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test

procedures.

FIELD INSTALLED ACCESSORIES:

Plenum Adapter (RXAA-)............................................................
Fossil Fuel Kit: RXPF-F01 and F02  ..........................................
External Bottom Filter Rack: RXGF-CB ....................................
External Side Return Filter Rack: RXGF-CA..............................
Return Air Cabinets: RXGR-CB..................................................
Solid Bottom Kit: (RXGB-D14, 17, 21, 24) ................................
High Altitude Kit: (RXGY-F13 for 2 stage models only) ..............

UPFLOW/HORIZONTAL GAS FURNACES:

RGPN- Series
80% A.F.U.E.

Input Rates 50 to 150 kBTU [15 to 44 kW]

Annual Fuel Utilization Efficiency - 

AFUE

THIS MODEL

ENER      UIDE

97%

78%

HIGH

MID

82%

88%

80.0%

0.552219s