Rheem 82V120HE-1 User's Manual

Rheem Water Heater User's Manual - 82V120HE-1.
Download
Page  of 1
4.2, 1060 votes
background image

Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117 • www.rheem.com

P R I N T E D I N U . S . A

0 6 / 0 8 W P

F O R M N O . 1 0 1 - 1 6 R e v. 1 3

In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.

HOT

COLD

VALVE

RELIEF

8"

B

WATER CONNECTION NIPPLES
ALL 3/4" N.P.T.

COLD
INLET

HOT

OUTLET

A

COLLECTOR

RETURN

COLLECTOR

FEED

WATER CIRCULATOR

(REQUIRED FOR NON-

GRAVITY SYSTEMS)

SO

LA

R E

NE

RG

Y

CO

LLE

CT

OR

SU

ITA

BL

E F

OR

PO

TA

BL

E W

AT

ER

AN

D P

RO

PY

LEN

E

GY

LC

OL

SO

LU

TIO

N

7"

DESCRIPTION

ROUGHING IN DIMENSIONS (SHOWN IN INCHES)

ENERGY INFORMATION

ELEMENT

APPROX.

APPROX.

GAL.

WATTAGE

HEIGHT

DIAMETER

SHIP WT.

R-

CAP.

MODEL NUMBER

UPPER

A

B

(LBS.)

FACTOR

T
Y
P
E

80

81V80HE-1

4500 W*

58-3/4

24-1/2

222

R-17.3

80

81V80HE-T

Storage only

58-3/4

24-1/2

222

R-17.3

120

82V120HE-1

4500 W*

62

28-1/4

380

R-17.3

120

82V120HE-T

Storage only

62

28-1/4

380

R-17.3

Solaraide

™ HE Solar Heat Exchanger, SolarTank, or Electric Storage Water Heater

Available in 80 and 120 Gallon Models

 6-Year Limited Tank and Parts Warranty*
• Brass drain valve

• Choice of two models…storage tank or

single element water heater specifically
engineered for installation with residential
indirect solar systems

• Temperature and pressure relief valve included

• Collector feed and return fittings located at

front of tank for convenient installation

• Isolated tank design for better heat

retention

• High efficiency heating element

• Rheemglas® tank lining resists corrosion and

prolongs tank life

• Heat exchanger: copper tubing wrapped

around and secured to the tank.
Double wall, vented design for positive
leak detection

• Cold water inlet brings cold water to tank

bottom to prevent mixing with heated water

• Anode rod equalizes aggressive water action

for prolonged tank life

• Cold water inlet, hot water outlet, relief valve

and anode rod at top of tank for easy access
and fast, economical installation

• Automatic temperature control

• Over temperature protector

* See Residential Warranty Information Brochure

for complete warranty information.

* Heaters furnished with standard 240 volt AC, single phase non-simultaneous wiring and 4500 watt heating element.
• If heating elements of different wattages than those shown are demanded by zone requirements, they must be specifically requested.
• To prevent corrosion, proper pH levels in transfer fluid must be maintained.
• Solaraide models meet all current state requirements for solar storage tanks.
• The tanks are Rheemglas lined and are designed to operate up to 150 PSI.

A special 1/2" NPT
opening 
is provided
for installation of a
“probe type”
thermostat.

COPPER COIL DATA (Type L Copper)

Maximum pressure = 150 PSI

Maximum temperature = 185° F

Tube I.D. = 5/8"

Solaraide HE

Coil Capacity

Length of Tubing

Tank Capacity

Gallons

Around Tank (Ft)

80 Gallons

2.2

120

120 Gallons

2.6

143

PRESSURE DROP THROUGH COIL (Feet of H

20)

Head Loss (Feet)

Flow Rate

80 Gallon

120 Gallon

1 GPM

1.3

1.6

2 GPM

4.8

5.7

3 GPM

10.0

12.0

Related Manuals for Rheem 82V120HE-1

0.601283s