ReliOn BP300 Owner's Manual

ReliOn Healthcare Owner's Manual - BP300.
Download
Page  of 2
4.4, 2216 votes
background image

SAFETY INFORMATION

INTENDED USE

This monitor is designed to measure blood pressure and pulse rate of adults within the 

range of the designated arm cuff, following the directions provided in this instruction 

manual.  The monitor is designed for home use. Read the Safety Information in this 

instruction manual before using this monitor.

To assure the correct use of the product, basic safety measures should always be 

followed including the warnings and cautions listed in this instruction manual.

OPERATING THE DEVICE

Contact your physician for specific information about your blood pressure. 

Self-diagnosis and treatment using measured results may be dangerous. Follow the 

instructions of your physician or licensed healthcare provider.
DO NOT adjust medication based on measurement results from this blood pressure 

monitor. Take medication as prescribed by your physician. Only a physician is 

qualified to diagnose and treat High Blood Pressure.
The monitor is not intended to be a diagnostic device.
If battery fluid should get in your eyes, immediately rinse with plenty of clean 

water. Contact a physician immediately.
Read all of the information in the instruction manual and any other literature in the 

box before operating the unit.
Do not use this device on infants or persons who cannot express their intentions.
Read the Special Conditions section of the instruction manual if your systolic 

pressure is known to be more than 220 mmHg. Inflating to a higher pressure than 

necessary may result in bruising where the cuff is applied.
Operate the device only as intended. Do not use the device for any other purpose.
Dispose of the device, components and optional accessories according to applicable 

local regulations. Unlawful disposal may cause environmental pollution.
Do not use a cellular phone near the device. It may result in an operational failure.
Use only authorized parts and accessories. Parts and accessories not approved for 

use with the device may damage the unit.
Use only 1.5V Alkaline batteries with this device. Other types of batteries may 

damage the unit.
Do not use in a location with moisture, or a location where water may splash on the 

unit.

RISK OF ELECTRICAL SHOCK

Do not plug or unplug the power cord into the electrical outlet with wet hands.
Do not overload power outlets. Plug the device into the appropriate voltage outlet.

CARE AND MAINTENANCE

Do not subject the monitor to strong shocks, such as dropping the unit on the floor.
Do not submerge the device or any of the components in water.
Store the device and the components in a clean, safe location.
Changes or modification not approved by the manufacturer will void the user 

warranty. Do not disassemble or attempt to repair the unit or components.

SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL

WARNING

Indicates a potentially hazardous situation which, if not avoided, 

could result in death or serious injury.

CAUTION

Indicates a potentially hazardous situation which, if not avoided, 

may result in minor or moderate injury to the user or patient or 

damage to the equipment or other property.

BEFORE TAKING A MEASUREMENT

To ensure a reliable reading follow these recommendations:

1.  Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes 

before taking a measurement. Rest for at least 15 minutes before taking the 

measurement.

2.  Stress raises blood pressure. Avoid taking measurements during stressful times.

3.  Measurements should be taken in a quiet place.

4.  Remove tight-fitting clothing from your left arm.

5.  Sit on a chair with your feet flat on the floor. Rest your left arm on table so that the 

cuff is at the same level as your heart.

6.  Remain still and do not talk during the measurement.

7.  Wait 2-3 minutes between measurements. The wait time allows the arteries to return 

to the condition prior to taking the blood pressure measurement. You may need to 

increase the wait time depending on your individual physiological characteristics.

8.  Keep a record of your blood pressure and pulse readings for your physician. A 

single measurement does not provide an accurate indication of your true blood 

pressure. You need to take and record several readings over a period of time. Try to 

measure your blood pressure at the same time each day for consistency.

INSTRUCTION MANUAL

Automatic 

Blood Pressure Monitor

Model  7400REL

INTRODUCTION

Thank you for purchasing the ReliOn® 7400REL Automatic Blood Pressure Monitor.

Your new blood pressure monitor uses the oscillometric method of blood pressure 

measurement. This means the monitor detects your blood’s movement through your 

brachial artery and converts the movements into a digital reading. An oscillometric 

monitor does not need a stethoscope so the monitor is simple to use.

The 7400REL comes with the following components:

• Monitor • Wide Range Cuff  • AC Adapter

• Instruction Manual printed in English and Spanish • Quick Start Guide

Please read this instruction manual thoroughly before using the unit.

Please keep for future reference.

For specific information about your own blood pressure, CONSULT YOUR 

DOCTOR.

Fill in for future reference.

DATE PURCHASED: __________________

SERIAL NUMBER: ____________________

• Staple your purchase receipt here

SAVE THESE INSTRUCTIONS

9494942-9A

LIMITED WARRANTY

Your ReliOn® 7400REL Automatic Blood Pressure Monitor, excluding the arm cuff, is 

warranted to be free from defects in materials and workmanship appearing within 5 

years from the date of purchase, when used in accordance with the instructions 

provided with the monitor. The arm cuff is warranted to be free from defects in 

materials and workmanship appearing within one year from the date of purchase when 

the monitor is used in accordance with the instructions provided with the monitor. The 

above warranties extend only to the original retail purchaser.
We will, at our option, repair or replace without charge any monitor or arm cuff 

covered by the above warranties. Repair or replacement is our only responsibility and 

your only remedy under the above warranties.
To obtain warranty service contact Customer Service by calling 1-800-634-4350 for the 

address of Inspection center.
Enclose the Proof of Purchase. Include a letter, with your name, address, phone 

number, and description of the specific problem. Pack the product carefully to prevent 

damage in transit. Because of possible loss in transit, we recommend insuring the 

product with return receipt requested.
THE FOREGOING IS THE SOLE WARRANTY PROVIDED BY OMRON IN 

CONNECTION WITH THIS PRODUCT, AND OMRON HEREBY DISCLAIMS 

ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 

PURPOSE. IMPLIED WARRANTIES AND OTHER TERMS THAT MAY BE 

IMPOSED BY LAW, IF ANY, ARE LIMITED IN DURATION TO THE PERIOD 

OF THE ABOVE EXPRESS WARRANTY.

OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER 

SPECIAL, INCIDENTAL, CONSEQUENTIAL OR INDIRECT COSTS, 

EXPENSES OR DAMAGES.

This warranty provides you with specific legal rights, and you may have other rights 

that vary by jurisdiction. Because of special local requirements, some of the above 

limitations and exclusions may not apply to you.

FOR CUSTOMER SERVICE

Visit our web site at:                                                              www.omronhealthcare.com

Call toll free:                                                                                            1-800-634-4350

Note:
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only)
This product has been tested and found to comply with the limits for a Class B digital 

device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful interference 

in a residential installation. The product generates, uses, and can radiate radio 

frequency energy and, if not installed and used in accordance with the instructions, 

may cause harmful interference to radio communications. However, there is no 

guarantee that interference will not occur in a particular installation. If the product does 

cause harmful interference to radio or television reception, which can be determined by 

turning the product on and off, the user is encouraged to try to correct the interference 

by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the product and the receiver.
• Connect the product into an outlet on a circuit different from that to which the 

receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for Canada only)
This digital apparatus does not exceed the Class B limits for radio noise emissions 

from digital apparatus as set out in the interference-causing equipment standard entitled 

“Digital Apparatus”, ICES-003 of the Canadian Department of Communications.
Cet appareil numérique respecte les limites de bruits radioeléctriques applicables aux 

appareils numériques de Clase B prescrites dans la norme sur le materiel brouilleur: 

“Appareils Numériques”, ICES-003 édictée par le minister des communications.

Changes or modifications not expressly approved by the party responsible for 

compliance could void the user’s authority to operate the equipment.

SPECIFICATIONS

Model:
Display:
Measurement Range:
Accuracy/Calibration:

Inflation:
Deflation:
Rapid Air Release:
Measurement Method:
Power Source:
Battery Life:
Operating Temperature 
/Humidity:
Storage Temperature 
/Humidity/Air Pressure:
Main Unit Weight:

Main Unit Dimensions:

Cuff Size:

Cuff Circumference:

Memory:
Contents:

Optional Accessories:

7400REL (HEM-8722-WM)
LCD Digital Display
Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min.
Pressure: ±3mmHg or 2% of reading

Pulse: ±5% of reading
Automatic by electric pump
Automatic pressure release valve
Automatic exhaust valve
Oscillometric method
120V 60Hz AC adapter or 1.5V 4 "AA" batteries
Approx. 300 uses with 4 new alkaline batteries
50ºF to 104ºF (10ºC to 40ºC) /15 to 90% RH

-4ºF to 140ºF (-20ºC to 60ºC) /10 to 95% RH

700-1060 hPa
Approximately 13 3/8 oz. (380g)

not including batteries
Approx. 6"(l) × 4 7/8"(w) × 3 1/2" (h)

(152 mm × 123 mm × 88 mm)
Approx. 6"(w) × 22 1/8"(l) (151 mm × 563 mm)

Cuff tube 35 3/8" (900 mm)
Fits arm circumferences 9" to 17"

(220 mm to 420 mm)
Up to 100 readings per user
Main Unit, Wide Range Cuff, AC Adapter, Instruction 

Manual, and Quick Start Guide
Wide Range Cuff 9'' - 17'' (220mm - 420mm), AC Adapter

NOTE: These specifications are subject to change without notice.
Manufactured for OMRON HEALTHCARE Co., Ltd.
Made in China
Distributed by OMRON HEALTHCARE, INC.

1925 West Field Court

Lake Forest, IL 60045 U.S.A.

www.omronhealthcare.com
© 2012 OMRON HEALTHCARE, INC.

ReliOn® is a registered trademark used under license by OMRON HEALTHCARE, 

INC.

.................................................................

Distributed by:

Wal-Mart® Stores, Inc.

Bentonville, AR 72716

FCC STATEMENT

HEM-8722-WM_A_M09_120831.pdf

SETTING THE DATE AND TIME

WARNING

If battery fluid should get in your eyes, immediately rinse with

plenty of clean water. Contact a physician immediately.

CAUTION

Read all of the information in the instruction manual and any other

literature in the box before operating the unit.

CAUTION

This device is intended for use in measuring blood pressure and

pulse rate in the adult population. Do not use this device on infants

or persons who cannot express their intentions.

APPLYING THE CUFF ON THE LEFT ARM

1.  Make sure the air plug is securely inserted 

in the main unit.

2.  Remove tight-fitting clothing from your upper 

arm.

3.  Apply the cuff to your left upper arm so 

the arrow is centered on the inside of your arm 

and aligned with your middle finger. 

The air tube runs down the inside of your arm. 

The bottom of the cuff should be 

approximately 1/2 " above your elbow.

4. Wrap the cuff firmly in place around your 

arm using the cloth fastening.

APPLYING THE CUFF ON THE RIGHT ARM

When taking a measurement using the right arm, use this instruction for Step 3.

Apply the cuff to your right upper arm so 

the arrow and the air tube runs along the inside 

of your arm. The bottom of the cuff should be 

approximately 1/2 " above your elbow.

NOTE: Be careful not to rest your arm on the air tube. This will restrict the flow of air 

to the cuff.

APPLYING THE ARM CUFF

1/2 inch (1 - 2 cm)

Air Tube

Arrow

Left Arm

Right Arm

Arrow

TAKING A MEASUREMENT

The monitor is designed to store the blood pressure and the pulse rate in the memory 

for two people (USER A or USER B) every time a measurement is completed.

1.  Sit on a chair with your feet flat on the floor. 

Place your arm on a table so the cuff is level 

with your heart. 

Keep still and do not talk during measurement.

2.  Select your USER ID (A or B).

CARE AND MAINTENANCE

To keep your blood pressure monitor in the best condition and protect the unit from 

damage, follow the directions listed below:
Do not forcefully bend the arm cuff or air tube. Do not fold tightly.
Clean the monitor with a soft dry cloth.

Do not use any abrasive or volatile cleaners.

Do not attempt to clean the cuff.

CAUTION

Do not submerge the device or any of the components in water. Do

not subject the monitor to extreme hot or cold temperatures,

humidity or direct sunlight.

CAUTION

Store the device and the components in a clean, safe location.

CAUTION

Do not subject the monitor to strong shocks, such as dropping the unit on the floor.

Remove the batteries if the unit will not be used for three months or longer. Always 

replace all the batteries with new ones at the same time.
Use the unit in a manner consistent with the instructions provided in this manual.

CAUTION

Use only authorized parts and accessories. Parts and accessories not 

approved for use with the device may damage the unit.

CAUTION

Changes or modification not approved by the manufacturer will void the user 

warranty. Do not disassemble or attempt to repair the unit or components.

TROUBLESHOOTING TIPS

PROBLEM

No power.

No display appears on the unit.

Measurement values appear too 

high or too low.

CAUSES AND SOLUTIONS

Replace all four batteries with new ones.

Check the battery installation for proper placement 

of the battery polarities.
Blood pressure varies constantly. Many factors 

including stress, time of day, how you wrap the 

cuff, may affect your blood pressure. 

Review the sections “Before Taking a 

Measurement” and “Taking a Measurement”.

ERROR INDICATORS

1.  Press the hook on the top of the battery cover and lift the 

cover off in the direction of the arrow.

2.  Install 4 “AA” size batteries so the + (positive) and

 - (negative) polarities match the polarities of 

the battery compartment as indicated.

3.  Replace the battery cover.

BATTERY REPLACEMENT

Low Battery Indicator

When the Low Battery Indicator appears on the display, turn the monitor off and 

remove all the batteries. Replace with four new batteries at the same time. Long-life 

alkaline batteries are recommended.

NOTES:   Turn the unit off before replacing the batteries. If the batteries are removed 

while the unit is still on, the date and time will be reset to that of the 

previous use. However, the measurement results are not deleted.

• When the batteries are replaced, you may need to reset the date and time. If 

“-:--” appears on the display, refer to “Setting the Date and Time”.

CAUTION

Dispose of the device, components and optional accessories according to 

applicable local regulations. Unlawful disposal may cause environmental 

pollution.

BATTERY INSTALLATION

UNIT DISPLAY

KNOW YOUR UNIT

Main Unit:

Components:

SET 
button

Wide Range Cuff

AC Adapter

Air tube

Air plug

Quick Start 
Guide

Instruction 
Manual

DISPLAY SYMBOLS

IRREGULAR HEARTBEAT SYMBOL (       )
When the monitor detects an irregular rhythm two or more times during the 

measurement, the Irregular Heartbeat Symbol (       ) will appear on the display with the 

measurement values.
An irregular heartbeat rhythm is defined as 

a rhythm that varies by less than 25% from 

the average rhythm or 25% more than the 

average rhythm detected while the monitor 

is measuring the systolic and diastolic 

blood pressure.
If the irregular heartbeat symbol (        ) 

displays with your measurement results, 

we recommend you consult your 

physician. Follow the directions of your 

doctor.
MOVEMENT ERROR SYMBOL (       )
The Movement Error Symbol (        ) is displayed if you move your body during the 

measurement. Please remove the arm cuff, and wait 2-3 minutes. Reapply the arm cuff 

and take another measurement.
AVERAGE VALUE SYMBOL (       )
The Average Value Symbol (        ) is displayed when you press the memory button. 

The most recent average reading appears on the display screen.
HEARTBEAT SYMBOL (      )

The Heartbeat symbol flashes on the display at every heartbeat during the 

measurement.

Normal Heartbeat

Irregular Heartbeat

Short Long

Blood 

pressure

Pulse

Pulse

Blood 

pressure

Systolic blood pressure

Diastolic blood pressure

Memory symbol

Average value symbol

Heartbeat symbol

Irregular heartbeat symbol

USER ID symbol (A/B)

Blood pressure level indicator

Pulse display and Memory number

Deflation symbol

Battery low indicator

Date/Time Display

Movement error symbol

 

 

   

 

 

 

USING THE AC ADAPTER

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE  INSTRUCTIONS

For connection to a power supply not in the U.S.A., use an

attachment plug adapter of the proper configuration for the power

outlet.

The power unit (AC Adapter) is intended to be correctly oriented

in a vertical or floor mount position.

Do not plug or unplug the power cord into the electrical outlet with 

wet hands.

Do not overload power outlets. Plug the device into the appropriate

voltage outlet.

Use only authorized parts and accessories. Parts and accessories not

approved for use with the device may damage the unit.

1.  Insert the AC Adapter Plug into the 

AC Adapter Jack on the right side 

of the monitor as illustrated.

2.  Plug the AC Adapter into a 120V 

AC outlet (60 cycles).

1.  Hold and pull the Housing to remove the AC Adapter from the electrical 

outlet. Do not remove by pulling the cord.

2.  Remove the AC Adapter plug from the monitor.

TO CONNECT THE AC ADAPTER

TO DISCONNECT THE AC ADAPTER

• Use only the authorized AC Adapter included with this monitor.

• We recommend you install the batteries even if the AC Adapter is 

used. If no batteries are installed, you may need to reset the date 

and time if the AC Adapter is disconnected. The measurement 

results will not be deleted.

- DANGER -

TO REDUCE THE RISK OF

FIRE OR ELECTRIC SHOCK,

CAREFULLY FOLLOW THESE INSTRUCTIONS.

NOTES:

CAUTION

WARNING

WARNING

Housing

Cord

The year flashes on the display.

2.  SETTING THE YEAR

The year can be set between 2013 and 2040. When the 

display reaches 2040, it will return to 2013.

Press the Up button (      ) to advance by one year.

Press the SET button to set the current year.

The month flashes on the display.

NOTES:  Press the Down button (      ) to decrease the 

date and time values.

• Press and hold the button to increase or 

decrease the date and time values faster.

3.  SETTING THE MONTH

Press the Up button (      ) to advance by one month.

Press the SET button to set the current month.

The day flashes on the display.

4.  SETTING THE DAY

Press the Up button (      ) to advance by one day.

Press the SET button to set the current day.

The hour flashes on the display.

5.  SETTING THE HOUR

The time is set using AM or PM.

Press the Up button (      ) to advance by one hour.

Press the SET button to set the current hour.

The minute flashes on the display.

6.  SETTING THE MINUTE

Press the Up button (      ) to advance by one minute.

Press the SET button to set the minute setting.

7.  TO TURN THE MONITOR OFF

Press the ON/OFF button.

NOTE: The monitor will automatically turn off 2 minutes 

after the minute has been set.

Set the monitor to the current date and time before taking a measurement for the first 

time.

1.  TO START THE SETTING

Press the SET button to adjust the date and time.

3.  Press the ON/OFF button. All symbols appear on the display.

The cuff starts to inflate automatically. As the cuff inflates, the monitor automatically 

determines your ideal inflation level. 

Remain still and do not move your arm until the entire measurement process is completed.

NOTE: To stop the inflation or measurement, push the ON/OFF button. The 

monitor will stop inflating, start deflating, and will turn off.

4.  Inflation stops automatically and the measurement is started.

As the cuff deflates, decreasing numbers appear on the display and the Heartbeat 

Symbol (     ) flashes.

5.  When the measurement is complete, the arm cuff completely 

deflates. Your blood pressure and pulse rate are displayed.

The 1999 WHO/ISH guidelines for the management of hypertension are as follows:

This is a general guideline because blood pressure depends on age and morbidity.

A lower home blood pressure goal may be recommended for certain patients, 

including diabetic patients, pregnant women, and patients with renal failure.

6.  Press the ON/OFF button to turn the monitor off.

NOTE: The monitor will automatically turn off after 2 

minutes.

WARNING

Contact your physician for specific information about your blood pressure.

Self-diagnosis and treatment using measured results may be dangerous.

Follow the instructions of your physician or licensed healthcare provider.

WARNING

DO NOT adjust medication based on measurement results from this blood

pressure monitor. Take medication as prescribed by your physician. Only a

physician is qualified to diagnose and treat High Blood Pressure.

WARNING

The monitor is not intended to be a diagnostic device.

SPECIAL CONDITIONS

CAUTION

Inflating to a higher pressure than necessary may result in bruising where 

the cuff is applied.
If your systolic pressure is known to be more than 220 mmHg, press and 

hold the ON/OFF button until the monitor inflates 30 to 40 mmHg higher 

than your expected systolic pressure, after the cuff starts to inflate.

NOTES:   Do not apply more pressure than necessary.

• The monitor will not inflate above 299 mmHg.

When the measurement is complete, the arm cuff completely deflates.

Your blood pressure and pulse rate are displayed.

Systolic blood pressure

Red 

above 139 mmHg

Yellow 

130 - 139 mmHg

Green 

129 mmHg or less 

Diastolic blood pressure

Red 

above 89 mmHg

Yellow 

85 - 89 mmHg

Green 

84 mmHg or less 

Press the Up (       ) or Down (       ) button 

to display the next set of values.

NOTE:

 Press and hold the Up or Down button to display the values faster.

TO DELETE ALL VALUES STORED IN THE MEMORY

The values stored in the memory are deleted by USER ID.

You cannot partially delete values stored in the memory. All values for

the user you select will be deleted.

1. Select your USER ID (A or B).

2. While holding the Memory button (     ), press the ON/OFF button down 

for more than 2 seconds until the display appears as it does in the 

following illustration.

3. Press the ON/OFF button to turn the monitor off.

NOTE: The monitor will automatically turn off after 2 minutes.

Air plug disconnected.

Arm cuff not applied 

correctly.
Air is leaking from the 

arm cuff.

Cuff over or under 

inflated.

Device error.

Batteries are worn.

Movement during 

measurement.

Clothing is interfering 

with the arm cuff.

Insert the plug securely. Refer to 

“Applying the Arm Cuff”.
Apply the arm cuff correctly. Refer to 

“Applying the Arm Cuff”.

Do not inflate the cuff above 299 mmHg. 

Refer to “Taking a Measurement”.

Remove any clothing interfering with the 

arm cuff. Refer to “Applying the Arm 

Cuff”.

Replace the four batteries.

Refer to “Battery Installation”.

Repeat measurement. Remain still and do 

not talk during measurement. Refer to 

“Taking a Measurement”.

Repeat measurement. Remain still and do 

not talk during measurement. Refer to 

“Taking a Measurement”.

If “E2” appears repeatedly, inflate the cuff 

manually until it is 30 to 40 mmHg above 

your previous measurement result. Refer 

to “Taking a Measurement”.

Replace the cuff with a new one.

Contact Customer Service.

The arm cuff was inflated 

above 299 mmHg when 

inflating the cuff manually.

SYMBOL

CAUSE

CORRECTION

ON/OFF button

Memory button

USER ID 
Selection Switch

Up/Down (                    ) buttons

Air Jack

Display

: to display the older readings

: to display the recent readings

INSTRUCTION MANUAL

Automatic 

Blood Pressure Monitor

Model  7400REL

INTRODUCTION

Thank you for purchasing the ReliOn® 7400REL Automatic Blood Pressure Monitor.

Fill in for future reference.

DATE PURCHASED: __________________

SERIAL NUMBER: ____________________

9494942-9A

USING THE MEMORY FUNCTION

The monitor automatically stores up to 100 sets of measurement values (blood pressure 

and pulse rate) for each user (A or B). When 100 sets of measurement values are 

stored, the oldest record is deleted to save the most recent values.

AVERAGING FUNCTION

The monitor calculates the average reading based on the three most recent sets of 

measurement values taken within 10 minutes of the most recent reading.

NOTES: • If two sets of measurement values are stored in the memory for the 10 

minutes period, the average is based  on the two sets of measurement 

values. If one set of measurement values is stored, this is displayed as the 

average.

• When viewing the reading taken without setting the date and time, "-:--" is 

displayed instead of the date and time.

• The average reading will not be calculated without setting the date and time.

TO DISPLAY THE MEASUREMENT VALUES

1. Select your USER ID (A or B).

2. Press the Memory button (     ).

The Average Symbol (     ) appears on the display when the average 

reading is shown.

AC Adapter Jack

Battery compartment

Battery Cover

7400REL

Automatic

Blood Pressure

Monitor

Blood Pressure Monitor

Quick Start Guide

3. Press the Down button (        ) to display the most recent set of 

measurement values on the screen. The values are displayed from the most 

recent to the oldest.

NOTES:

 • The Memory number appears for 

a second before the pulse rate is 

displayed. The newest set is 

number “1”.

• The date and time are alternately 

displayed with the measurement 

values.

Alternating display

Category / Blood pressure

Hypertension
High-Normal

Normal

Systolic blood pressure

above 139 mmHg

130 - 139 mmHg

129 mmHg or less

Diastolic blood pressure

above 89 mmHg

85 - 89 mmHg

84 mmHg or less

0.688790s