SELECTION OF LOCATION
Select a convenient location where:

INDOOR UNIT

!

The cool air can reach every corner of the 
area to be cooled.

!

The unit is away from any direct heat 
source

!

Easy and short routing of the refrigerant 
and drain pipes to the exterior.

!

There are no flammable gas, alkaline or 
acid present in the air.

!

Air circulation is not obstructed, preventing 
good air circulation.

!

The structure where the unit is installed 
should be strong enough to support the 
weight of the unit and also prevent any 
vibration during operation of the unit.

!

Figure on the right shows the spacing to the 
nearest wall.

OUTDOOR UNIT:

!

The condensing unit should be located as 
close as possible to the fan coil.

!

The air inlet shall be located at least 4” from 
the wall or other obstruction for unrestricted 
airflow.

!

The air outlet shall be located so as to 
direct discharged warm air away from the 
building.  (Avoid low overhanging roofs to 
avoid re-circulation of condenser discharge 
air on vertical discharge models.)

!

Mount the unit on a sturdy base.

!

Figure on the right shows the spacing to be 
provided.