External Control                                    NEC LCD Monitor 

1. Application 
 This document defines the communications method for control of the NEC LCD monitor, MultiSync X461UN 
/X461HB /X431BT /P401 /P461 /P521 /P701 /S401 /S461 /S521 and MULTEOS M401 /M461 /M521 when using 

an external controller

.

 

 

2. Connectors and wiring 
2.1 RS-232C Remote control 

  Connector: 9-pin D-Sub 
 Cable: Cross (reversed) cable or null modem cable 
 

(Please refer 

“Controlling the LCD monitor via RS-232C Remote control” on User’s manual.) 

 
2.2 LAN control 

  Connector: RJ-45 10/100 BASE-T 
 Cable: Category 5 or higher LAN cable 
 

(Please refer 

“Controlling the LCD monitor via LAN control” on User’s manual.) 

 
3. Communication Parameter 
3.1 RS-232C Remote control 

(1) Communication system 

Asynchronous 

(2) Interface   

 

RS-232C 

(3) Baud rate   

 

9600bps 

(4) Data length 

 

8bits 

(5) Parity 

 

 

None 

(6) Stop bit 

 

 

1 bit 

(7) Communication code   

ASCII 

 

3.2 LAN control 

(1) Communication system 

TCP/IP (Internet protocol suite)  

(2) Interface   

 

Ethernet (CSMA/CD) 

(3) Communication layer  

Transport layer (TCP)  

 

 

 

 

* Using the payload of TCP segment. 

(4) IP address  

 

(Default) 192.168.0.10 

 

 

 

 

* If you need to change, 

 

 

 

 

Please refer 

“Network settings” on User’s manual. 

(5) Port No. 

 

 

7142 (Fixed) 

 
(Note) 
The monitor will disconnect the connection if no packet data is received for 15 minutes. 
And the controller (PC) has to re-connect to control the monitor again, after 15 minutes or more. 
 

3.3 Communication timing 

The controller should wait for a packet interval before next command is sent. 
The packet interval needs to be longer than 600msec for the LCD monitor.

 

 

 