Maytag UXI1200DYS Dimension Guide

Maytag Ovens Dimension Guide - UXI1200DYS.
Download
Page  of 1
4.9, 2194 votes
background image

600 CFM and 1200 CFM In-Line Blowers for Range Hoods

PRODUCT MODEL NUMBERS

LOCATION REQUIREMENTS

UXI0600DY

UXI1200DY

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10331013

12/21/10

Electrical Requirements: A 120 volt, 60 Hz, AC only, 15- or 

20-amp, fused electrical circuit is required.

IMPORTANT: Observe all governing codes and ordinances.

Have a qualified technician install the in-line blower motor system.
All openings in the ceiling and wall where the in-line blower motor
system will be installed must be sealed.
For Mobile Home Installations

The installation of this in-line blower motor system must conform to
the Manufactured Home Construction Safety Standards, Title 24 CFR,
Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local
codes.

PRODUCT DIMENSIONS

Top (outlet) view 

Bottom (inlet) view 

26

¹⁄₈" (66.4 cm)

14

¹¹⁄₁₆" 

(37.3 cm)

24

³⁄₄" (62.9 cm)

14

⁷⁄₈" 

(20.0 cm)

3

³⁄₈" 

(8.6 cm)

12

¹⁵⁄₁₆" 

(32.9 cm)

16

¹⁄₈" (41.0 cm)

14

⁷⁄₈" 

(20.0 cm)

3

³⁄₈" 

(8.6 cm)

VENTING REQUIREMENTS

● 

The vent system must terminate to the outdoors.

● 

Do not terminate the vent system in an attic or other enclosed area.

● 

Do not use 4" (10.2 cm) laundry-type vent or wall caps.

● 

Use round, metal vent only. Rigid metal vent is recommended. Plastic or metal
foil vent is not recommended.

● 

The length of the vent system and number of elbows should be kept to a
minimum to provide efficient performance.

For the most efficient and quiet operation:

● 

Use no more than three 90° elbows.

● 

Make sure there is a minimum of 24" (61.0 cm) of straight vent between the
elbows if more than 1 elbow is used.

● 

Do not install 2 elbows together.

● 

Use clamps to seal all joints in the vent system.

● 

The vent system must have a damper.

● 

Use weatherproof caulking to seal the exterior wall or roof opening around the
cap.

● 

The size of the vent should be uniform. 

Calculating Vent System Length

To calculate the length of the system you need, add the equivalent length for
each vent piece used in the system.

Vent Piece 

Equivalent Length

45° elbow 2.5 

ft

(0.8 m)

90° elbow 5.0 

ft

(1.5 m)

The maximum equivalent vent lengths are:
10" (25.4 cm) round vents - 60 ft (18.3 m)

Example vent system

The following example falls within the maximum recommended vent length.

1 - 90° elbow 

= 5.0 ft (1.5 m)

1 - wall cap 

= 0.0 ft (0.0 m)

8 ft (2.4 m) straight 

= 8.0 ft (2.4 m)

Length of system 

= 13.0 ft (3.9 m)

90  elbow

6 ft (1.8 m)

2 ft

(0.6 m)

Wall cap

0.471197s