GROUNDING INSTRUCTIONS

SAVE THESE INSTRUCTIONS

■  

For a grounded, cord-connected dryer: 

This dryer must be grounded. In the event of malfunction or 
breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This dryer is equipped with a cord having an equipment- 
grounding conductor and a grounding plug. The plug must 
be plugged into an appropriate outlet that is properly 
installed and grounded in accordance with all local codes 
and ordinances.
WARNING: Improper connection of the equipment- 

grounding conductor can result in a risk of electric shock. 
Check with a qualified electrician or service representative 
or personnel if you are in doubt as to whether the dryer is 
properly grounded. Do not modify the plug provided with 
the dryer: if it will not fit the outlet, have a proper outlet 
installed by a qualified electrician.

Electric Dryer Power Hookup – 

Canada Only
Electrical Requirements

It is your responsibility:

 

To contact a qualified electrical installer.

 

To be sure that the electrical connection is adequate  

and in conformance with the Canadian Electrical Code, 

C22.1-latest edition and all local codes. A copy of the  

above codes standard may be obtained from: Canadian 

Standards Association, 178 Rexdale Blvd., Toronto, ON  

M9W 1R3 CANADA.

 

To supply the required 4 wire, single phase, 120/240 volt,  

60 Hz., AC only electrical supply on a separate 30-amp 

circuit, fused on both sides of the line. A time-delay fuse or 

circuit breaker is recommended. Connect to an individual 

branch circuit.

 

This dryer is equipped with a CSA International Certified 

Power Cord intended to be plugged into a standard 14-30R 

wall receptacle. The cord is 5 ft. (1.52 m) in length. Be sure 

wall receptacle is within reach of dryer’s final location.

4-wire receptacle (14-30R)

 

Do not use an extension cord.

If using a replacement power supply cord, it is recommended 

that you use Power Supply Cord Replacement Part Number 

8579325. For further information, please reference the 

“Assistance or Service” section of the “Use and Care Guide.”

Gas Dryer Power Hookup
Electrical Requirements

 

120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical 

supply is required. A time-delay fuse or circuit breaker is 

recommended. It is also recommended that a separate  

circuit serving only this dryer be provided.