Maytag MGC9536DS Dimension Guide

Maytag Cooktop Dimension Guide - MGC9536DS.
Download
Page  of 4
4.3, 1217 votes
background image

PRODUCT MODEL NUMBERS

KCGS350E
KCGS356E
KCGS550E
KCGS556E 

KCGS950E
KCGS956E
MGC7430D
MGC7536D

MGC9530D 
MGC9536D
WCG51US0D
WCG51US6D

WCG75US0D
WCG97US0D
WCG97US6D 

GAS SUPPLY REQUIREMENTS

Type of Gas

Natural Gas:

This cooktop is design-certified by CSA International for use with Natural gas or,
after proper conversion, for use with LP gas.

● 

This cooktop is factory set for use with Natural gas. If converting to LP gas, see
the “LP Gas Conversion” instructions provided in the package containing
literature. The model/serial rating plate located on the underside of the cooktop
base has information on the types of gas that can be used. If the types of gas
listed do not include the type of gas available, check with the local gas supplier.

LP Gas Conversion:
Conversion must be done by a qualified service technician.

No attempt shall be made to convert the cooktop from the gas specified on the
model/serial rating plate for use with a different gas without consulting the serving
gas supplier. See the Gas Conversion instructions provided in the package
containing literature.

Gas Supply Line

● 

Provide a gas supply line of 

³⁄₄" (1.9 cm) rigid pipe to the cooktop location. A

smaller size pipe on longer runs may result in insufficient gas supply. Pipe-joint
compounds that resist the action of LP gas must be used. Do not use TEFLON®†
tape. With LP gas, piping or tubing size should be 

¹⁄₂" minimum. Usually, LP gas

suppliers determine the size and materials used in the system.

Flexible metal appliance connector:

● 

If local codes permit, use a 

¹⁄₂" or ³⁄₄" I.D. flexible stainless steel tubing gas

connector, designed by CSA to connect the cooktop to the rigid gas supply line.

● 

¹⁄₂" male pipe thread is needed for connection to the female pipe threads of the

inlet to the cooktop pressure regulator.

● 

Do not kink or damage the flexible metal tubing when moving the cooktop.

ELECTRICAL REQUIREMENTS

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10597144A

9/10/14

Page 1 of 4

● 

A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is required. A time-

delay fuse or circuit breaker is also recommended. It is recommended that a

separate circuit serving only this cooktop be provided.

● 

Electronic ignition systems operate within wide voltage limits, but proper

grounding and polarity are necessary. Check that the outlet provides 120-volt

power and is correctly grounded.

†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

● 

Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This valve should
be located in the same room but external to the cooktop opening, such as an
adjacent cabinet. It must be accessible without removing the cooktop, and it
should be in a location that allows ease of opening and closing. Do not block
access to shutoff valve. The valve is for turning on or shutting off gas to the
cooktop.

A. Gas supply line
B. Shutoff valve “open” position

C. To cooktop

A

B

C

30" (76.2 CM) AND 36" (91.4 CM) GAS BUILT-IN COOKTOP

Related Manuals for Maytag MGC9536DS

0.609529s