30" (76.2 cm) Freestanding Gas Range

PRODUCT MODEL NUMBERS

PRODUCT DIMENSIONS

MGR7661W

MGR7662W

MGR7685A

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10526974A

2/13/13

A. 27

⁷⁄₈" (70.8 cm) max. depth with handle

B. 36" (91.4 cm) cooktop height (max.) with leveling legs 

screwed all the way in*

C. 46

⁷⁄₈" (119.1 cm) overall height (max.) with leveling 

legs screwed all the way in*

D. 29

⁷⁄₈" (75.9 cm) width

E. 25

⁷⁄₁₆" (64.6 cm) depth. Back of range to front of 

cooktop**

F. Model/serial rating plate (located on the oven frame 

behind the top left side of the oven door)

A

B

C

D

E

F

IMPORTANT: Range must be level after installation. Follow the instructions in the
“Level Range” section. Using the cooktop as a reference for leveling the range is not
recommended.
**Range can be raised approximately 1" (2.5 cm) by adjusting the leveling legs.
**Front of door and drawer may extend further forward, depending on styling.

Electrical Requirements

A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time-
delay fuse or circuit breaker is also recommended. It is recommended that a
separate circuit serving only this range be provided.

Gas Supply Requirements

Type of gas

Natural gas:

This range is design-certified by CSA International for use with Natural gas or,
after proper conversion, for use with LP gas.

● 

This range is factory set for use with Natural gas. See “Gas Conversions”
section. The model/serial rating plate located on the oven frame behind the
top left side of the oven door has information on the types of gas that can be
used. If the types of gas listed do not include the type of gas available, check
with the local gas supplier.

LP gas conversion:

Conversion must be done by a qualified service technician. No attempt shall be
made to convert the appliance from the gas specified on the model/serial
rating plate for use with a different gas without consulting the serving gas
supplier. See “Gas Conversions” section.
Gas Supply Line

● 

Provide a gas supply line of 

³⁄₄" (1.9 cm) rigid pipe to the range location. A

smaller size pipe on longer runs may result in insufficient gas supply. With
LP gas, piping or tubing size can be 

¹⁄₂" (1.3 cm) minimum. Usually, LP gas

suppliers determine the size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be used.
Do not use TEFLON®† tape.

Flexible metal appliance connector:
● 

If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to 
152.4 cm) long, 

¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible metal appliance

connector may be used for connecting range to the gas supply line.

● 

¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the female pipe

threads of the inlet to the appliance pressure regulator.

● 

Do not kink or damage the flexible metal tubing when moving the range.

Rigid pipe connection:

The rigid pipe connection requires a combination of pipe fittings to obtain an
in-line connection to the range. The rigid pipe must be level with the range
connection. All strains must be removed from the supply and fuel lines so
range will be level and in line.

● 

Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This valve
should be located in the same room but external to the range opening, such
as an adjacent cabinet. It should be in a location that allows ease of opening
and closing. Do not block access to shutoff valve. The valve is for turning on
or shutting off gas to the range.