MODEL: T1975

PROGRAM TIME SWITCH WITH “SKIPPER@”

FOR UP TO 48 TIMING OPERATIONS 

ON 24 HOUR SCHEDULE

SINGLE POLE DOUBLE THROW

SWITCH RATING:  20 AMP. 125-480 VOLTS A.C. 1/2 HP-125V 1 HP-250V.

WIRING INSTRUCTIONS

This  Time  Switch  can  be  wired  to  control  two  circuits  as  Single  Pole 

Double throw, or to control one circuit as Single Pole Single Throw. Either  

normally open (NO) or normally closed (NC). To wire switch see wiring 

diagram  above.
                 

TO PROGRAM TIME SWITCH, Depress tripper(s) into dial at desired 

time(s) operation(s) is/are required.

• ON TIME: First tripper turns on the load for 16-20 minutes. Each  

additional tripper will lengthen the on time by 15  minutes.

 OFF TIME: First tripper in raised position turns off the load for 10-14 

minutes.Each additional space will lengthen the of time by 15 minutes.
SET  TIME-OF-DAY:  Turn  dial  in  clockwise  direction  only  and  align 

the  exact  time-of-day  (the  time  now  when  switch  is  being  put  into 

operation) to the “TIME” arrow on insulator.
CHECK  SKIPPER  WHEEL.  If  switch  is  to  function  seven  days  a 

week pull all pins, in skipper wheel up to “OUT” position. Otherwise 

depress pin(s) in skipper wheel for day(s) automatic operation is not 

required.

• If, after the dial is set to the correct time of day and the skipper

   tripper  (silver  color)  has  not  yet  passed  the  skipper  wheel,  turn 

   wheel counter clockwise so that the previous day is opposite the 

   “DAY” arrow.

• Iftheskippertripperhasalreadypassedtheskipperwheelsetthe

   correct day opposite the “DAY” arrow.

 

 

CLOCK

MOTOR

SUPPLY

NORMALLY  CLOSED  CIRCUIT

NORMALLY  OPEN CIRCUIT

                             FIG. 1                                                       WIRING DIAGRAM

CLOCK

COM.

N.C.

LOAD

NO.

LOAD

1.

2.

3.

OPERATING INSTRUCTIONS

TO  CONTROL  LOADS  MANUALLY,  Move  manual  lever  (See  Figure 

1)  up.  This  lever  will  close  normally  open  circuit  and  open  the  normally 

closed  circuit.  To  return,  to  automatic  control,  move  lever  back  to  its 

original position .

IN CASE OF POWER FAILURE, reset dial. See step (2) of programming 

instructions.

INTERMATIC INCORPORATED

SPRING GROVE, ILLINOIS 60081-9698

158TS12894                                                        

                                                                                                                                                      

CLOCK MOTOR: 125 VOLTS - 60 HZ.

CLOCK MOTOR VOLTAGE AND CYCLE MUST BE AS SPECIFIED. TO ORDER 

REPLACEMENT, INDICATE PART NO. (WG--) ON MOTOR COVER.

LR3730

TIME

DIAL

INSULATOR

MANUAL

LEVER

CAP
NUTS

SKIPPER

WHEEL