Intermatic T1906 Owner's Manual

Intermatic Misc Electronics Owner's Manual - T1906.
Download
Page  of 1
4.8, 2375 votes
background image

PROGRAM TIME SWITCH

FOR UP TO 48 TIMING OPERATIONS

ON 24 HOUR SCHEDULE

SINGLE POLE DOUBLE THROW

SWITCH RATING:  20 AMP. 125-480 VOLTS A.C. 1/2 HP-125V  1 HP-250V.

WIRING INSTRUCTIONS

This  Time  Switch  can  be  wired  to  control  two  circuits  as  Single  Pole 

Double throw, or to control one circuit as Single Pole Single Throw. Either  

normally open (NO) or normally closed (NC). To wire switch see wiring 

diagram  above.

TO PROGRAM TIME SWITCH, Depress tripper(s) into dial at desired 

time(s) operation(s) is/are required.

• ON TIME: First tripper turns on the load for 16-20 minutes. Each  

additional tripper will lengthen the on time by 15  minutes.

•  OFF  TIME:  First  tripper  in  raised  position  turns  off  the  load  for 

10-14 minutes.Each additional space will lengthen the of time by 15 

minutes.
SET  TIME-OF-DAY:  Turn  dial  in  clockwise  direction  only  and  align 

the  exact  time-of-day  (the  time  now  when  switch  is  being  put  into 

operation) to the “TIME” arrow on insulator.

TIME

DIAL

INSULATOR

MANUAL

LEVER

CAP
NUTS

CLOCK

MOTOR 

SUPPLY

NORMALLY  CLOSED  CIRCUIT

NORMALLY  OPEN CIRCUIT

                              FIG. 1                                                               WIRING DIAGRAM

CLOCK

COM.

N.C.

N.O.

N.C.

LOAD

NO.

LOAD

1.

2.

OPERATING INSTRUCTIONS

TO  CONTROL  LOADS  MANUALLY,  Move  manual  lever  (See  Figure 

1)  up.  This  lever  will  close  normally  open  circuit  and  open  the  normally 

closed  circuit.  To  return,  to  automatic  control,  move  lever  back  to  its 

original position .

IN CASE OF POWER FAILURE, reset dial. See step (2) of programming 

instructions.

TO REMOVE MECHANISM FROM CASE, Disconnect electricity and all 

wiring. Depress retainer spring at upper left, or unscrew mounting screws, 

then grasp dial and pull mechanism out.

INTERMATIC INCORPORATED

SPRING GROVE, ILLINOIS 60081-9698

154--00920                                                  

CLOCK MOTOR: 208- 277 VOLTS - 60 HZ.

CLOCK MOTOR VOLTAGE AND CYCLE MUST BE AS SPECIFIED. TO ORDER 

REPLACEMENT, INDICATE PART NO. (WG--) ON MOTOR COVER.

LR3730

Model T1906