IRN37 - 160K - CC & IRN50 - 200H & IRN75 - 160K - 2S & IRN - 100 - 200H - 2S & IRN 250 - 300H - 2S

http://air.irco.com

7

When using compressed air always use appropriate 
personal protective equipment.

All pressure containing parts, especially flexible hoses 
and their couplings, must be regularly inspected, be free 
from defects and be replaced according to the Manual 
instructions.

Compressed air can be dangerous if incorrectlyhandled. 
Before doing any work on the unit, ensure that all 
pressure is vented from the system and that the machine 
cannot be started accidentally.

Avoid bodily contact with compressed air.

The safety valve located in the separator tank must be 
checked periodically for correct operation.

Whenever pressure is released through the pressure relief 
valve, it is due to excessive pressure in the system. The 
cause for the excessive pressure should be investigated 
immediately.

Materials

The following substances are used in the manufacture 
of this machine and may be hazardous to health if used 
incorrectly:

preservative grease
rust preventative
compressor coolant

 WARNING

AVOID INGESTION, SKIN CONTACT AND 

INHALATION OF FUMES

For further information, request and consult the coolant 
Material Data Sheet (UK ACGP 011/96 −ULTRA COOLANT 
ACGP 029/90−food grade coolant. For USA served areas, 
use MSDS sheet APDD 236) from your local IR office, 
Distributor or Air Center.

Should compressor lubricant come into contact with the 
eyes, then irrigate with water for at least 5 minutes.

Should compressor lubricant come into contact with the 
skin, then wash off immediately.

Consult a physician if large amounts of compressor 
lubricant are ingested.

Consult a physician if compressor lubricant is inhaled.

Never give fluids or induce vomiting if the patient is 
unconscious or having convulsions.



The above information contains data supplied in support 
of United Kingdom Control of Substances Hazardous to 
Health
 (C.O.S.H.H.) regulations

Transport

When loading or transporting machines ensure that the 
specified lifting and tie down points are used.

It is recommended that the machine be moved using the 
fork lift slots in the machine base.

Refer to section 8-General Information for reference 
information.

Electrical

The compressor has high and dangerous voltage in the 
motor starter and control box. All installations must be 
in accordance with recognized electrical codes. Before 
working on the electrical system, be sure to remove 
voltage from the system by using a manual disconnect 
switch. A circuit breaker or fuse safety switch must be 
provided in the electrical supply line leading to the 
compressor.

Those responsible for installation of this equipment 
must provide suitable grounds, maintenance clearance 
and lightning arrestors for all electrical components in 
accordance with National and Local code requirements.

Keep all parts of the body and any hand−held tools or 
other conductive objects, away from exposed live parts 
of the compressor electrical system. Maintain dry footing, 
stand on insulating surfaces and do not contact any other 
portion of the compressor when making adjustments or 
repairs to exposed live parts of the compressor electrical 
system.

Close and lock all access doors when the compressor is 
left unattended.

Do not use extinguishers intended for Class A or Class B 
fires on electrical fires. Use only extinguishers suitable for 
class BC or class ABC fires.

Attempt repairs only in clean, dry, well lighted and 
ventilated areas.

Connect the compressor only to electrical systems that 
are compatible with its electrical characteristics and that 
are within it’s rated capacity.

5.0 SAFETY