Hunter XC Programming Instructions Manual | Page 6

Hunter Misc Electronics Programming Instructions Manual - XC.
Download
Page  of 18
4.4, 2477 votes
background image

SEN

C P 1 2 3 4 5 6 7 8

RST

24VAC

BAT

Valve Common Wire

Connect the Two

Transformer Wires to

the Two AC Terminals

Valve 1

Valve 2

Valve 3

Valve 4

Valve

Wires

MOUnTInG THE COnTROLLER TO WALL

NOTE: The indoor XC is not waterproof or weather resis-

tant, and must be installed indoors or in a protected area. 

1.  Secure one screw into the wall. Install screw anchors if attaching 

to drywall or masonry wall.

2.  Slide the keyhole on top of the controller over the screw.
3.  Secure the controller in place by installing screws in the holes 

below the terminal strip.

Do not plug transformer into power source until control-

ler is mounted and all valve wiring has been connected.

COnnECTInG VALVEs AnD TRAnsFORMER
Installation of the XC should only be done by trained personnel.
1.  Route valve wires between the control valve location and controller.
2.  At valves, attach a common wire to either solenoid wire on all 

valves. This is most commonly a white colored wire. Attach a 

separate control wire to the remaining wire of each valve. All wire 

connections should be done using waterproof connectors.

3.  Route the valve wires through the conduit. Attach the conduit 

through the bottom right side of the controller.

4.  Secure the white valve common wire to the C (Common) screw on 

the terminal strip. Attach each of the individual valve control wires 

to the appropriate station terminals and tighten their screws.

5. 

Indoor Models: route the transformer cable through the hole on 

the left side of the controller and connect the wires to the two 

screws marked 24VAC.

 

Outdoor Models: transformer wires are already connected to the 

AC terminals so all that is required is to connect primary power to 

the junction box (see below).

E – High Voltage Wiring (Outdoor Model only)

NOTE: XC outdoor models are water and weather resis-

tant. Connecting the outdoor XC to primary AC power 

should only be done by a licensed electrician following 

all local codes. Improper installation could result in 

shock or fire hazard.

1.  Route AC power cable and conduit through the ½" (13mm) conduit 

opening on the left side bottom of the cabinet.

2.  Connect one wire to each of the two wires inside the junction box. 

The ground wire should be connected to the green wire. Wire nuts 

are provided to make these connections. Note: For –E models 

only: Connect the wires to the AC terminal block inside the junc-

tion box. AC supply wires must be 14 AWG (1.85mm) or larger 

with appropriate circuit breaker for the wire size. A switch or cir-

cuit-breaker shall be included in the building installation (in close 

proximity to the controller, within easy reach of the operator) and 

marked as the disconnecting device for the equipment.

3.  Replace the junction box cover.

ACTIVATInG THE BATTERy
After installing your XC make sure to remove the bat-

tery contact insulator to allow the XC to keep time in 

the event of a power outage.