Hotpoint RVM5160DHCC Installation Instructions | Page 6

Hotpoint Microwave Oven Installation Instructions - RVM5160DHCC.
Download
Page  of 52
4.4, 2199 votes
background image

 

 

 

EQUIVALENT 

 

 NUMBER 

  EQUIVALENT

DUCT PIECES 

       

LENGTH   

USED 

 

LENGTH 

 

   

 

   

Rectangular-to-Round   

5 Ft. 

 

(    ) 

 

 

 

Ft. 

  

  Transition 

Adaptor*

 

   

 

 

 

 Wall 

Cap   40 

Ft. 

 x ( 

 

 

 

 =   Ft.

 

   

 

 

 

 90° 

Elbow 

  10 

Ft. 

 x ( 

 

 

 

 =   Ft.

 

   

 

 

 

 45° 

Elbow 

  5 

Ft. 

 x ( 

 

 

 

 =   Ft.

 

   

 

 

 

 90° 

Elbow 

  25 

Ft. 

 x ( 

 

 

 

 =   Ft.

 

   

 

 

 

 45° 

Elbow 

  5 

Ft. 

 x ( 

 

 

 

 =   Ft.

 

   

 

 

 

 Roof 

Cap   24 

Ft. 

 x ( 

 

 

 

 =   Ft.

  

  Straight 

Duct 

6s Round or 

1 Ft. 

 

(    ) 

 

 

 

Ft. 

 

   

31ø4s x 10s Rectangular

 

   

 

 

 

 

 

 

 

7RWDO'XFWZRUN  

)W

Equivalent lengths of duct pieces are based on actual tests and 

reflect requirements for good venting performance with any vent 

hood.

6

*  IMPORTANT: If a rectangular-to-round transition 

adaptor is used, the bottom corners of the damper 

will have to be cut to fit, using the tin snips, in order 

to allow free movement of the damper.

NOTE: If you need to install ducts, note that the total duct 

length of 31ø4s x 10s rectangular or 6s diameter round duct 
VKRXOGQRWH[FHHGHTXLYDOHQWIHHW
Outside ventilation requires a HOOD EXHAUST DUCT.  

Read the following carefully:
NOTE: It is important that venting be installed using  

the most direct route and with as few elbows as possible.  

This ensures clear venting of exhaust and helps prevent 

blockages. $OVRPDNHVXUHGDPSHUVVZLQJIUHHO\DQG
QRWKLQJLVEORFNLQJWKHGXFWV

Exhaust connection: 
The hood exhaust has been designed to mate with  

a standard 31ø4s x 10s rectangular duct.
If a round duct is required, a rectangular-to-round  

transition adaptor must be used. Do not use less than  

a 6s diameter duct.

0D[LPXPGXFWOHQJWK
For satisfactory air movement, the total duct length of  

31ø4s x 10s rectangular or 6s diameter round duct should 
QRWH[FHHGHTXLYDOHQWIHHW

Elbows, transitions, wall and roof caps, etc., 

present additional resistance to airflow and are equivalent 

to a section of straight duct which is longer than their actual 

physical size. When calculating the total duct length, add the 

equivalent lengths of all transitions and adaptors plus the 

length of all straight duct sections. The chart below shows 

you how to calculate total equivalent ductwork length using 

the approximate feet of equivalent length of some typical 

duct pieces.

Installation Instructions