INSTALLATION INSTRUCTIONS

TECHNICAL DATA
Gas connection

Rp ½ (½" BSP female)

Pressure test point

Front left hotplate injector

Gas rate adjustment

None

Aeration adjustment

None

Electrical connection

4mm2 twin and earth
230/240V a.c. 50Hz.

CH60DTXF S S  CH60DTCF S  

HEAT INPUT

INJECTOR

HEAT INPUT

INJECTOR

HOTPLATE

Front Left

4.1 kW

100+72+100

3.8 kW (275g/h)

63+42+63

HOTPLATE

Rear Right

 3.05 kW

116

3.0 kW (220g/h)

86

HOTPLATE
Front Right and Rear Left

 2.0 kW

103

2.0 kW (145g/h)

70

TOTAL LOAD

4.5 / 4.9 kW

!"

HEAT INPUT

INJECTOR

HEAT INPUT

INJECTOR

HOTPLATE
Front Left and Rear Right

3.05 kW

116

3.0 kW (220g/h)

86

HOTPLATE
Front Right and Rear Left

 2.0 kW

103

2.0 kW (145g/h)

70

TOTAL LOAD

4.5 / 4.9 kW

    CH60DPCF S   CH60DPXF S  