BEFORE YOU BEGIN

Installation  

Range Hood  

Instructions 

 

Read these instructions completely and carefully.

‡

 

IMPORTANT – Save these instructions for 

local inspector’s use.

‡

 

IMPORTANT – Observe all governing 

codes and ordinances.

‡

Note to Installer – Be sure to leave these 

instructions with the Consumer.

‡

Note to Consumer – Keep these instructions 

for future reference.

‡ 6NLOOOHYHO² Installation of this appliance requires 

basic mechanical and electrical skills.

‡ &RPSOHWLRQWLPH² 30 minutes–3 hours
‡  Proper installation is the responsibility of the installer. 
‡  Product failure due to improper installation is not 

covered under the Warranty.

NOTE: 5HDGWKHGXFWZRUNVHFWLRQVRQO\LI\RXGRQRW
KDYHH[LVWLQJGXFWZRUN,I\RXKDYHH[LVWLQJGXFWZRUN
VNLSWRWKH´'DPDJHµVHFWLRQDQGSURFHHG

WARNING – 725('8&(7+(5,6.2)),5($1'

723523(5/<(;+$867$,5%(685(72'8&7$,52876,'(³
'21279(17(;+$867$,5,17263$&(6:,7+,1:$//625
&(,/,1*625,172$77,&6&5$:/63$&(625*$5$*(6
The venting system must exhaust to the outside.
This hood can be vented vertically through upper cabinets or 

horizontally through an outside wall. Ductwork is not included.
([KDXVWFRQQHFWLRQ

The hood exhaust has been designed to mate with 

standard 31ø4s x 10s rectangular ducting or 7s diameter 

round ducting.
If a 6s round duct is required, a rectangular-to-round 

transition adaptor must be used*. Do not use less than a 

6s diameter duct.

0D[LPXPGXFWOHQJWK

For satisfactory air movement, the total duct length 

of a 31ø4s x 10s rectangular, 6s or 7s diameter round 

duct VKRXOGQRWH[FHHGHTXLYDOHQWIHHW6HH

WKH:25.6+((7²&$/&8/$7(727$/(48,9$/(17

'8&7:25./(1*7+VHFWLRQ
NOTE: 
It is important that ducting be installed using the 

most direct route and with as few elbows as possible. 

This ensures clear venting of exhaust and helps prevent 

blockages. Also, make sure dampers swing freely and 

nothing is blocking the ducts. When applicable, install any 

makeup (replacement) air system in accordance with local 

building code requirements. Visit GEAppliances.com for 

available makeup air solutions.
(OERZVWUDQVLWLRQVZDOODQGURRIFDSVHWF 

present additional resistance to airflow and are equivalent 

to a section of straight duct longer than their actual 

physical size. When calculating the total duct length, add 

the equivalent lengths of all transitions and adaptors plus 

the length of all straight duct sections. The charts on the 

following pages show you how to calculate total equivalent 

ductwork length using the approximate feet of equivalent 

length of some typical ducts.

'8&7:25.5(48,5(0(176

WARNING – Before beginning the 

installation, switch power off at service panel and  

lock the service disconnecting means to prevent power  

from being switched on accidentally. When the service 

disconnecting means cannot be locked, securely fasten 

a prominent warning device, such as a tag, to the 

service panel.

)25<2856$)(7<

Questions? Call 800.GE.CARES (800.432.2737) RUYLVLWRXU:HEVLWHDW GEAppliances.com

An optional Power Cord Connection Kit, model JXHC1,  

is available at extra cost from your GE supplier for 

installation using a standard 3-prong, grounded wall 

outlet. Follow the Installation Instructions packed with 

the kit to connect the power cord to the range hood.

OPTIONAL POWER CORD KIT JXHC1

6

*  IMPORTANT:  If a rectangular-to-round 

transition adaptor is used, the bottom 

corners of the damper will have to be 

cut to fit, using the tin snips, in order 

to allow free movement of the damper. 

Equivalent lengths of duct pieces  

are based on actual tests and reflect 

requirements for good venting 

performance with any hood.