Honeywell RLV310A Owner's Manual

Honeywell Thermostats Owner's Manual - RLV310A.
Download
Page  of 4
4.7, 1383 votes
background image

RLV310

      69-1869ES                    9/1/05                    1/4

This thermostat can be used to control an electric heating system
such as a baseboard heater, a radiant ceiling, a radiant floor, a con-
vector, etc.
The thermostat cannot be used with the following:

a resistive load under 2 A

a resistive load over 12.5 A

systems driven by a contactor or a relay (inductive load)

fan-equipped heating systems

central heating systems

SUPPLIED PARTS

One (1) thermostat

Two (2) 6-32 mounting screws

Two (2) solderless connectors

TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRIC SHOCK.
Loosen the screw holding the control module to the base. The screw
cannot be completely removed. Lift the control module to remove it
from the base.

Make the appropriate connections. Please note that the thermostat
wires are non-polarized; either wire can be connected to either termi-
nal.

NOTE:  All cables and connections must conform to the local electri-
cal code. Special CO/ALR solderless connectors must be used when
connecting with aluminium conductors.

Align and affix the base to the
electrical box.

Set the switch at the back of the remov-
able part of the thermostat to °C or °F.

Replace the front part of the thermostat
on the base and secure it in place with
the screw.
Keep air vents of thermostat clean and
free from obstructions.

Description

1.

Installation

2.

Temperature 
display 

Heating power 
indicator

Temperature 
adjustment 
buttons

2-wire installation

4-wire installation

RLV310

User Guide

Electronic Thermostat

0.489492s