GENERAL INFORMATION
The ADEMCO 6150V and ADEMCO 6160V are addressable
remote keypads designed for use with ADEMCO control
panels and provide the following features:
• Backlit Display
• Voice Chime
• Programmable Function Keys
• Built-in Sounder
• Voice Status
• Message Center
• Supervised by control panel (if supported)
Notes:
• When used with the ADEMCO VISTA-15P/VISTA-
20P control panels, address 16 must be assigned to
the first keypad. Additional keypads must be
assigned to address 17 – 23. Refer to Setting The
Keypad Options.
• Keypad keys are continuously backlit for convenience.
• Permanent display backlighting is an option on some
controls (refer to control panel’s instructions for details).
• Voice Chime should only be enabled when used with
control panels that support the "chime by zone" mode
(e.g., VISTA-15P/VISTA-20P). This mode must be
enabled at the control panel. Refer to the control panel's
installation and setup guide for information on how to
program the chime mode.
• Use only zone descriptors supported by this
keypad. If using zone descriptors not supported
by this keypad, you must turn voice status and
voice chime off. Table 1 is a list of applicable zone
descriptors and index entries. Refer to the control
panel’s installation and setup guide for information
about how to program zone descriptors.
• For the 6160V ONLY, supervision must be enabled for
commercial fire installations.
UL NOTE: ADEMCO 6150V cannot be used for commercial
fire applications.
KEYPAD DISPLAYS AND LEDS
The keypads have the following display features:
Model
Fixed
Word
Display
2-Line
Alpha
Display
2-Digit
Zone
Identifier
Custom
Zone
Descriptors
6150V
X X
6160V
X X
The following table identifies the keypad’s LEDs and
associated functions:
LED
Function
ARMED
Lights red when the system is armed in any mode.
READY
Lights green when the system is "ready" to be
armed.
MESSAGE
Flashes red when message waiting or lights red
(steady) when in record mode.
PROGRAMMABLE FUNCTION KEYS
The keypad's programmable function keys [A, B, C] are
normally used for keypad panic functions, but they can be
programmed for other special functions instead. If they are
programmed for other special functions, the associated
keypad key pairs still provide the respective panic alarm (if
programmed). Refer to the control panel’s Installation &
Setup Guide for details.
Function
Keys
Equivalent Key Pairs
A
[1] and [*]
B
[*] and [#]
C
[3] and [#]
D
NONE
•
Function keys must be held down for at
least 2 seconds to activate the programmed
function.
• If functions other than panics are assigned
to the programmable function keys,
programmed panics must be initiated by
pressing the programmed key pair.
FUNCTION KEY LABELS
A set of adhesive-backed labels with some typical function
symbols (i.e., fire, police, personal emergency, etc.) is
provided. These labels can be placed on or next to the keys
to identify each key's function for the end user (as
determined by the capability and programming of the
control panel; refer to the installation and setup guide for
the control panel).
6160V
-001-V1
MOUNTING RELEASE SNAPS
(Remove case back by pushing up the 2 "snaps" along
the keypad's bottom edge and pulling the case apart.)
1 OFF
4 MAX
7 INSTANT
READY
2 AWAY
5 TEST
8 CODE
0
3 STAY
6 BYPASS
9 CHIME
#
MESSAGE
MIC
ARMED
READY
RECORD
VOLUME
PLAY
STATUS
FUNCTION
VOICE
SIDE
VIEW
D
C
B
A
WIRING AND INSTALLATION
Keypads can be surface mounted using drywall anchors or
to a single- or double-gang electrical box.
1. Remove the case back by pushing up the two "snaps"
along the keypad’s bottom edge and pulling the case
apart. See diagram above.
2. Route wiring from the control panel through the
opening in the case back.
3. Mount the case back to a wall or electrical box.
4. Wire directly from the keypad’s terminal block to
the terminal block on the control board. (See Wiring
Table that follows.) Use only 16-24 AWG wire.
Wiring Table (All Keypads)
Keypad
Control Panel
Wire Color
G
Data In
Green
–
– Aux Pwr (GND)
Black
+
+ Aux. Pwr
Red
Y
Data Out
Yellow
5. Re-attach the keypad to the case back.
6. Remove clear protective film from LEDs (6160V
only).
Related Manuals for Honeywell Honeywell Door 6160V
-
GE Door 19200 GE Portable Wireless SevenSound Chime Owner's Manual
9 pages
-
GE Door 19208 GE Wireless SevenSound Door Chime One Push Button Owner's Manual
9 pages
-
GE Door 19209 GE Wireless SevenSound Door Chime Two Push Buttons Owner's Manual
9 pages
-
GE Door 19210 GE Wireless Push Button (White) Owner's Manual
6 pages
-
GE Door 19211 GE Wireless SevenSound Lighted Push Button Owner's Manual
2 pages
-
GE Door 19214 GE Direct Wire Door Chime Owner's Manual
1 pages
-
GE Door 19238 Wireless Door Chime Owner's Manual
2 pages
-
GE Door 19242 Wireless Door Bell Owner's Manual
9 pages
-
GE Door 19248 Door Chime With Pictures Coming Soon Owner's Manual
2 pages
-
Whirlpool Door AWZ 7913 WP Instruction Manual
9 pages
-
Wayne-Dalton Door FOAMCORE 9200 User's Manual
2 pages
-
Wayne-Dalton Door 8300/8500 User's Manual
26 pages
-
Honeywell Door ADEMCO 5828V User's Manual
2 pages
-
Sony Door SCHLAGE LINK BE369 User's Manual
7 pages
-
Heath Zenith Door Wireless Chime TR-0095-RX User's Manual
20 pages
-
Broan Door C305RW User's Manual
4 pages
-
M-Audio Door OXYGEN SERIES OXYGEN 8 V2 User's Manual
27 pages
-
BEA Door MC-Linx Assembly User's Manual
1 pages
-
Linear Door Electronic Access Control Cylindrical Lockset 212LS-C26DCR-LT User's Manual
2 pages
-
Schlage Door S-SERIES User's Manual
12 pages
-
Schlage Door king cobra User's Manual
6 pages
-
Schlage Door Programmable Electronic Deadbolt BE367 User's Manual
2 pages
-
Ace Hardware Door TR-0070-BX User's Manual
8 pages
-
SECO-LARM USA Door SK-2323-SPQ User's Manual
4 pages