Honeywell Honeywell Boiler L7224A User's Manual
INSTALLATION INSTRUCTIONS
68-0281-16
L7224A,C; L7248A,C,L
Oil and Electric Boiler
Electronic Aquastat® Controllers
APPLICATION
The L7224A,C and L7248A,C,L 2012 Compliant
Electronic Aquastat® Controllers provide electronic
temperature sensing in a UL limit-rated control with a
single sensing probe. The L7224A,C and L7248A,C,L
control the circulator, oil or electric burner or contactor,
and boiler temperature. The L7224/L7248 is “Outdoor
Temperature Reset” ready which is enabled when
connected to the W8735Y1000 wireless or W8735S1000
wired Outdoor Reset Kit. Outdoor Reset with the L7224/
L7248 is intended for all applications except for tankless
coil systems for domestic hot water. Compliance to 2012
DOE regulation ensures efficiency is maximized without
interfering with domestic hot water demand.
The L7224A,C and L7248A,C,L replace the L8124A,
L8124C, L7124A,C, L7148A and L8148A Control ers.
The L7224A,C and L7248A,C,L series controls provide
status and diagnostic information through an LED display
combined with LED lights as well as EnviraCOM™
communications enabled thermostats and diagnostic
tools to enhance the diagnostic process.
L7224/L7248 Aquastat Controllers are intended for use
in residential-type applications.
IMPORTANT
Use of Outdoor Temperature Reset on a tank-
less coil application requiring a Low Limit setting
will result in reduced system effectiveness and
efficiency.
SPECIFICATIONS
Electrical Ratings:
Voltage: 120 Vac, 60 Hz.
Power: 7 VA maximum at 120 Vac plus external loads.
Thermostat current: 100 mA nominal at 24 Vac.
Burner Relay:
7.4 A at 120 Vac Ful Load Amperage (FLA);
44.4 A inrush Locked Rotor Amperage (LRA);
Less Ignition Load: 360 VA.
Circulator Relay:
7.4 A at 120 Vac FLA; 44.4 A inrush LRA.
Zone Controller (ZC): 7.4 A at 120 Vac FLA;
44.4 A inrush LRA.
NOTE: All loads combined cannot exceed 2000 VA.
Environmental Ratings:
Temperature: -30 °F to +150 °F (-34 °C to +66 °C).
Humidity: 0 to 95% relative humidity, noncondensing.
Approvals:
Underwriters Laboratories Inc. Component Recognized.
Canadian Underwriters Laboratories Inc. Component
Recognized.
2012 DOE Compliance and Operation
Operation of this control may delay the burner operation while the residual heat is
circulated out of the boiler.
NOTE: This operation may be different than earlier electronic Aquastat®
revisions which did not implement thermal purge.
Related Manuals for Honeywell Honeywell Boiler L7224A
-
Baxi Boilers Combi Instant 80 HE and 105 HE Owner's Manual
12 pages
-
Baxi Boilers Solo 3 PFL Owner's Manual
8 pages
-
Baxi Boilers Solo 2 PF Quick Start Manual
44 pages
-
Baxi Boilers 105 HE Installation Manual
56 pages
-
Baxi Boilers Combi 80e Installation Manual
44 pages
-
Burnham Boilers SERIES 2 Instruction Manual
52 pages
-
Burnham Boilers V7 SERIES Operation Manual
47 pages
-
Burnham Boilers RSA BOILERS Instruction Manual
48 pages
-
Burnham Boilers V8 Series Instruction Manual
100 pages
-
Burnham Boilers ES2 ES2 Instruction Manual
52 pages
-
Burnham Boilers LEDV SERIES Instruction Manual
36 pages
-
Ferroli Boilers Modena 80 E User's Manual
44 pages
-
IDEAL Boilers MINI C24 User's Manual
4 pages
-
Saunier Duval Boilers THEMA F 23 E Installation Manual
28 pages
-
Vaillant Boilers ecoTEC plus SERIES Installation Manual
52 pages
-
Burnham Boilers MPO Series User's Manual
4 pages
-
Baxi Potterton Boilers Promax Combi HE Plus A Range G.C.No 47 393 22 User's Manual
60 pages
-
Baxi Potterton Boilers PERFORMA 30 HE User's Manual
12 pages
-
Keston Boilers Heat 55kw Installation Manual
60 pages
-
Keston Boilers C55 Installation Manual
54 pages
-
Keston Boilers C40 Installation Manual
54 pages
-
Viessmann Boilers Vitodens 200-W, B2HB Technical Manual
44 pages
-
Viessmann Boilers Vitodens 222-F, B2TA User's Manual
2 pages
-
Viessmann Boilers Vitola 200 Technical Manual
16 pages